Installation - MaxiScan 3100 network
MaxiScan 3010 - Installation Guide
13
Up to three MaxiScan 3100 units
adapter cable
P/N 3-510022-00
adapter cable
P/N 3-510022-00
MaxiScan 3010
RS-232 straight cable
P/N 0-530062-01
RS-485 network cable
1m P/N 3-504039-00
3m P/N 3-504039-01
MaxiScan 3100
terminator connector
P/N 3-500029-01
MaxiScan 3100
power supply
7 – 25V
If you are using a standard MaxiScan power supply (15 V), you can only connect
up to three MaxiScan 3100 units to the MaxiScan 3010 Network System.
If you want to connect more than three scanners, you must use the alternative
connection method using the MaxiScan Connection System described on the next
page or provide a power supply with sufficient power calculated as follows:
The power supply must withstand at least (n x 2.5 Watt) with peaks of up to two or three times this value
(n = number of MaxiScan 3100 scanners connected).
The value obtained does not take into account other external devices (synchronization devices, etc.) that may be
connected to the MaxiScan 3010 Network System
.
Warning: Power supply must be between 7 and 25 V.