Intermec EasyCoder 301 – Service Manual Ed. 3
12
Chapter 3
3. Front and Operator Interface
3.1
Front Panel
The printer's front panel is located at the top of the front cover (also
see chapter 3.2) and comprises a clear plastic window through
which a multi-colour LED (light-emitting diode) is visible and a
dome through which the Feed button switch can be activated.
The actual LED and switch are located on the Interface Module, see
chapter 3.2.
LED Control Lamp
The control lamp indicates the following conditions:
LED shows:
Meaning:
No light
Power Off
Green
(steady)
Power On
(flashing)
Busy (executing or receiving data)
(single flash)
Bar code successfully read
Amber
(steady)
Bar code wand active (lasts max. 10 sec:s)
(momentarily) During power on
Red
(steady)
Bar code wand inactive
Error, e.g.:
- Printhead lifted
- Out of paper
- Out of ribbon
1
- Paper jam in cutter
1
(single flash)
Bar code reading failed
Feed Button
The Feed button can be used for the following purposes:
• To feed out a blank label (before any label design has been
downloaded to the printer).
• To print a label after a label design has been downloaded to the
printer and the Feed button has been set up to work as a Print
button by means of a PRINT KEY ON command.
• To print a Test label and execute a TESTFEED operation. In this
case the Feed button must be kept pressed down during power
up. By pressing and holding the Feed button for 3 seconds after
printing the Test label, the printer will return to its default setup.
1
/. Not in the LinerLess model.