background image

4

Because of our commitment to continuing research and improvements, Intermatic Incorporated reserves the right to make changes, without notice, in the specifications and material 

contained herein and shall not be responsible for any damages, direct or consequential, caused by reliance on the material presented.

INTERMATIC INCORPORATED, SPRING GROVE, IL 60081-9698

http://www.intermatic.com

158AS11073

ONE YEAR LIMITED WARRANTY

If within the warranty period specified, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace

it, at its sole option, the unit free of charge. This warranty applies only to the original purchaser and is not transferable. This warranty does not apply
to: (a) damage caused by accident, abuse, mishandling, dropping, acts of God, or any negligent use; (b) units which have been subject to unautho-
rized repair, opened, taken apart, or otherwise modified; (c) units not used in accordance with instructions; (d) damages exceeding the cost of the
product. Some states do not allow a limitation of damages, so the foregoing limitation may not apply to you. This warranty gives you specific legal
rights and you may have other rights that vary from state to state.
INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. THIS WARRANTY IS IN LIEU OF ALL OTHER
EXPRESS OR IMPLIED WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF
FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY, AND SHALL BE
OF THE SAME DURATION AS THE WARRANTY PERIOD STATED ABOVE. 
This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased, or (b) mailing postage prepaid
to the nearest authorized service center listed. Please be sure to wrap the product securely when mailing to avoid shipping damage. This warranty is
made by: Intermatic Incorporated/After Sales Service, 7777 Winn Rd., Spring Grove, IL 60081-9698/815-675-7000  http://www/intermatic.com

WIRING DIAGRAM

Single Thermostat Heater

1. Connect two 18 gauge wires in

SERIES with Heater Switch.

2. Connect one of the wires to 

terminal “C” and the other to 
terminal “L”. INSTALL JUMPER
BETWEEN TERMINALS 
“L” AND “H”
.

3. Leave heater switch in ON position.

1. Connect three 18 gauge wires in

PARALLEL with Heater Switch.

2. Connect the wire from central post

(Common) of heater switch to 
terminal “C”, High to “H” and 
Low to “L”.

3. Leave heater switch in OFF position.

Dual Thermostat Heater

TIMER

NEUT

.

LINE

120/24V

.

TRANSFORMER

HEATER
SELECTOR
SWITCH

PULSE
SWITCH

AIR
HOSE

RELAY

240V.

BLOWER

120V.

SUPPLY

MEMORY
HOLD-UP
BATTERY

STEPPER RELAY

240V.

2-SPEED

PUMP

For single speed pump and/or 120 Volt equipment, follow wiring above except:
240 V. Single Speed Pump - Connect both BLUE and GRAY leads to LOAD 1 of pump.
120 V. Two Speed Pump - Connect NEUTRAL to WHITE lead and COMMON of pump.
120 V. Single Speed Pump - Connect NEUTRAL to WHITE lead and pump NEUTRAL. Connect both
BLUE 
and GRAY leads to pump LOAD terminal.
120 V. Blower - Connect NEUTRAL to blower NEUTRAL.

Отзывы: