3
OPERATION (Continued)
To Cancel/Change Part of the Program: Press
Timer key repeatedly until the particular ON or
OFF time appears. Set new ON or OFF time.
To Override the Automatic Operation one time:
Press OVR. key.
NOTE: Timer will resume automatic operation
with the next opposite setpoint.
To Override Automatic Operation Permanently:
Press SELECT key to move indicator bar to the
desired ON or OFF position. Note: Timer will not
resume automatic operation until indicator bar
is repositioned above the word AUTO.
To Operate Equipment in Spa Mode:
1. Press air button at spa side.
2. After using the spa, press air button again and
make sure that control is back in the POOL
mode.
To Operate Heater:
Heater Selector Switch is provided to save on heat-
ing cost during the summer months or prevent
over-heating of pool water if heater is the single
thermostat type.
Set switch to POOL AND SPA mode if the heater
is the DUAL thermostat type and set thermostats
on heater to the desired pool and spa water temper-
atures. Set switch to SPA ONLY mode if the heater
is the SINGLE thermostat type or only the spa
water needs to be heated. Set switch to OFF if no
heater operation is needed.
ENCLOSURE DETAILS
NOTES:
1. An air button with ruptured
seal or bellows inside, will
not produce sufficient air
pressure to operate the pulse
switch and could lead to total
breakdown allowing water
to enter the air hose.
2. Water in air hose can damage
the pulse switch. Water can
enter the air hose through a
faulty air button (see note 1
above) or by condensation.
In either case, it must be
drained, the cause found and
corrected. To reduce conden-
sation, protect the air hose
from exposure to direct sun,
ice or frequent temperature
TROUBLESHOOTING
Symptom
Possible Cause(s)
Corrective Action
Control will not operate
Air hose disconnected
Check hose connections
in SPA mode
Defective air button
Replace air button - see note 1
Water in air hose
Blow-out air hose - see note 2
Defective pulse switch
Replace pulse switch - see note 2
Defective relay
Replace relay
Air button is too far
Install larger air button
Blown fuse
Replace fuse
Timer is not turning
Defective timer
Replace timer
pump ON/OFF for
Defective relay
Replace relay
daily filtration
Timer is set to ON/OFF
Set timer to AUTO
No program in memory
Set program - see instructions
Dead battery
Replace battery
Valve actuators(s) is/are
Frozen valve
Check/Lubricate valve
not working
Defective actuator
Replace actuator
Loose connection
Check connections
Blown fuse
Replace fuse
Pump inoperative
Open circuit breaker
Check power supply
Defective relay
Change relay
Defective pump
Check pump