background image

3

OPERATION (Continued)

To Cancel/Change Part of the Program: Press
Timer key repeatedly until the particular ON or
OFF time appears. Set new ON or OFF time.

To Override the Automatic Operation one time:
Press OVR. key. 

NOTE: Timer will resume automatic operation

with the next opposite setpoint.

To Override Automatic Operation Permanently:
Press SELECT key to move indicator bar to the
desired ON or OFF position. Note: Timer will not

resume automatic operation until indicator bar

is repositioned above the word AUTO.

To Operate Equipment in Spa Mode:
1. Press air button at spa side.

2. After using the spa, press air button again and 

make sure that control is back in the POOL 
mode.

To Operate Heater:
Heater Selector Switch is provided to save on heat-
ing cost during the summer months or prevent
over-heating of pool water if heater is the single
thermostat type.
Set switch to POOL AND SPA mode if the heater
is the DUAL thermostat type and set thermostats
on heater to the desired pool and spa water temper-
atures. Set switch to SPA ONLY mode if the heater
is the SINGLE thermostat type or only the spa
water needs to be heated. Set switch to OFF if no
heater operation is needed.

ENCLOSURE DETAILS

NOTES:

1. An air button with ruptured 

seal or bellows inside, will 
not produce sufficient air 
pressure to operate the pulse
switch and could lead to total 
breakdown allowing water
to enter the air hose.

2. Water in air hose can damage 

the pulse switch. Water can 
enter the air hose through a 
faulty air button (see note 1 
above) or by condensation. 
In either case, it must be 
drained, the cause found and 
corrected. To reduce conden-
sation, protect the air hose 
from exposure to direct sun,
ice or frequent temperature 

TROUBLESHOOTING

Symptom

Possible Cause(s)

Corrective Action

Control will not operate 

Air hose disconnected

Check hose connections

in SPA mode

Defective air button

Replace air button - see note 1

Water in air hose

Blow-out air hose - see note 2

Defective pulse switch

Replace pulse switch - see note 2

Defective relay

Replace relay 

Air button is too far

Install larger air button

Blown fuse

Replace fuse

Timer is not turning

Defective timer

Replace timer 

pump ON/OFF for

Defective relay

Replace relay

daily filtration

Timer is set to ON/OFF

Set timer to AUTO

No program in memory

Set program - see instructions

Dead battery

Replace battery

Valve actuators(s) is/are

Frozen valve

Check/Lubricate valve

not working

Defective actuator

Replace actuator

Loose connection

Check connections

Blown fuse

Replace fuse

Pump inoperative

Open circuit breaker

Check power supply

Defective relay

Change relay

Defective pump

Check pump

RC2263BE

RC2263E

 

Отзывы: