![Intermatic PE650 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/intermatic/pe650/pe650_installation-and-user-manual_2078261010.webp)
10
I-Wave PE950/PE650 Installation Guide
Copyright © 2006 Intermatic, Inc.
Refer to page 32 of this manual for
information concerning setting the
temperatures for both your pool and spa.
Drill a 3/8” hole in the pipe between
the filter pump and filter and install the
Water Temperature Sensor with hose
clamp (not provided). Ensure the O-ring
is in place.
Run the wire to the Control Center,
through the low voltage raceway.
Connect both wires to the Panel-Mounted
Receiver. See the diagram below.
Connecting a Heater (optional)
The Intermatic I-Wave PE650 and
PE950 wireless components can control
most heaters or heat pumps that use
thermostatic circuitry of 24 VAC @ 2A or
•
•