PROBLEM
POSSIBLE CAUSE
REMEDY
G. Incorporative injector causing
1. Lube piston cannot dispense
1. Loosen the line fittings
the pump to stall.
lubricant.
individually from the injectors.
Actuate the
MANUAL OVERRIDE
AX3 only
button to identify the
stalled injector. Trace the line
and check for:
A. Clogged bearing.
B. Crimped line.
C. Blocked line.
2. Lube piston is frozen.
2. Loosen the injectors individually
from the pump body. Actuate
the
MANUAL OVERRIDE AX3
only
button to identify which
injector frees the system.
Replace the injector.
Check for contaminates in the
reservoir. Replace the lubricant
if contaminates are found.
H. Inoperative injector but the
1. Return spring on the injector is
1. Secure the return spring to the
pump is able to operate.
not attached.
lube piston and injector body.
2. Lube piston is missing.
2. Replace the injector.
3. Outlet check valve is not
3. Remove and clean the injector.
seating properly.
If this does not remedy the
problem, replace the injector.
Check for contaminates in the
reservoir. Replace the lubricant if
contaminates are found.
I. Lubricant is coming out of the
Broken or severed line.
Refer to
PROBLEM
“B – 1”.
tape / harness.