![Interlogix NX-595E Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/interlogix/nx-595e/nx-595e_installation-manual_2076778014.webp)
14
NX-595E Installation Manual
PCB Layout
Figure 7
Terminal descriptions
Terminal
Description
1 Pos
Panel
Bus
Positive terminal on the NetworX panel
2
Com
Common terminal on the NetworX panel
3
Data
Data terminal on the NetworX panel
4 V1+
NX-181xx
Audio
Lines
Audio Line A, positive
Green / White
5
V1-
Audio Line A, negative
Green
6
V2+
Audio Line B, positive
Orange / White
7
V2-
Audio Line B, negative
Orange
8 E1C
Entrance
camera 1
Common terminal on outdoor
station 1
Yellow
9
E1A
Audio terminal on outdoor
station 1
Red
10 E1+
Positive terminal on outdoor
station 1
Blue
11 E2C
Entrance
camera 2
Common terminal on outdoor
station 2
Yellow
12 E2A
Audio terminal on outdoor
station 2
Red
13 E2+
Positive terminal on outdoor
station 2
Blue
14 Z1
Additional
Zones
1
st
/ 3
rd
Zone
3K3 = Single EOLs
3K7 = Low zones
6K9 = High zones
15 Com
Common (-) return for Zone
loop
16 Z2
2
nd
/ 4
th
Zone
USBUP