background image

 

 

Copyright

 

© 2015 UTC Fire & Security Americas Corporation, Inc.  
All rights reserved. 
This document may not be copied in whole or in part or otherwise 
reproduced without prior written consent from UTC Fire & Security 
Americas Corporation, Inc., except where specifically permitted 
under US and international copyright law. 

Trademarks and 

patents

 

The NX-181xx name and logo are trademarks of UTC Fire & Security 
Americas Corporation, Inc. 
Other trade names used in this document may be trademarks or 
registered trademarks of the manufacturers or vendors of the 
respective products. 

Manufacturer

 

Placed on the market by: 
UTC Fire & Security Americas Corporation, Inc. 
3211 Progress Drive, Lincolnton, NC, 28092, USA 
Authorized EU manufacturing representative: 
UTC Fire & Security B.V. 
Kelvinstraat 7, 6003 DH Weert, Netherlands 

FCC compliance

 

This equipment has been tested and found to comply with the limits 
for a Class B digital device, pursuant to part 15 of the FCC Rules. 
These limits are designed to provide reasonable protection against 
harmful interference when the equipment is operated in a 
commercial environment. This equipment generates, uses, and can 
radiate radio frequency energy and, if not installed and used in 
accordance with the instruction manual, may cause harmful 
interference to radio communications. 
You are cautioned that any changes or modifications not expressly 
approved by the party responsible for compliance could void the 
user's authority to operate the equipment. 

NFPA 72 

 

Check local ordinances, this device is not listed by an approved test lab 
to meet NFPA 72 and therefore may not be sold or installed for use with 
a fire system in some localities. 

EU compliance

 

 

EU directives

 

UTC Fire & Security hereby declares that this device is in 
compliance with the applicable requirements and provisions of one 
or more of the Directives 1999/5/EC, 2014/30/EU and 2014/35/EU. 
For more information see: www.utcfireandsecurity.com or 
www.interlogix.com  

 

2012/19/EU (WEEE directive): 

Products marked with this symbol 

cannot be disposed of as unsorted municipal waste in the European 
Union. For proper recycling, return this product to your local supplier 
upon the purchase of equivalent new equipment, or dispose of it at 
designated collection points. For more information see: 
www.recyclethis.info.

 

 

2006/66/EC (battery directive): 

This product contains a battery that 

cannot be disposed of as unsorted municipal waste in the European 
Union. See the product documentation for specific battery 
information. The battery is marked with this symbol, which may 
include lettering to indicate cadmium (Cd), lead (Pb), or mercury 
(Hg). For proper recycling, return the battery to your supplier or to a 
designated collection point. For more information see: 
www.recyclethis.info.

 

Contact information 

 www.utcfireandsecurity.com or www.interlogix.com  

Customer support

 www.interlogix.com/customer-support 

or 

www.utcfssecurityproducts.eu 

 

Содержание NX-181xx NetworX

Страница 1: ...NX 181xx NetworX Voice keypad with touch buttons Installation Manual P N 230240 REV D ISS 11MAY15...

Страница 2: ...not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NFPA 72 Check local ordinances this device is not listed by an approved test lab...

Страница 3: ...4 Limitation of liability 4 Advisory messages 4 Disclaimer 5 Warranty 5 Installation 6 Wiring Structure Note 7 Advanced System Configuration 9 Panel and Device Configuration 13 Service provider phone...

Страница 4: ...iction is mandatory While every precaution has been taken during the preparation of this manual to ensure the accuracy of its contents UTCFS assumes no responsibility for errors or omissions Advisory...

Страница 5: ...em router firewall or any other 3rd party software Please consult your customers IT department or qualified IT professional about implementing this product onto your client s network Warranty UTC Fire...

Страница 6: ...te Insert a small flat head screwdriver until it is located under the locking tongue Whilst turning either clockwise or counter clock wise slide the NX 181xx down and clear of the locking tongue you c...

Страница 7: ...ed A maximum of 8 NX 181xx Voice keypads can be configured as room stations for intercom functionality Two pairs of twisted cable 4 conductors are required for the audio line one pair for audio line A...

Страница 8: ...X 181xx Voice keypads via the audio lines and a communication cable was specifically designed to transfer these recordings in installations that do not have dedicated audio cables installed please con...

Страница 9: ...Touch sense control Reserved Reserved Default keypad Go Back Keypad configuration Panel device configuration Service provider phone number Go Back Keypad tamper Entry exit beeps suppression Stay armin...

Страница 10: ...l and device configuration Touch 3 to configure service provider phone number Touch menu to exit 3 1 Selects Keypad configuration Announcement all keypad options are announced 4 Select one of the keyp...

Страница 11: ...to step 4 keypad option selection 4 5 Option 5 Number of hours to Auto Test Hours before next auto test is select hours before next auto test followed by enter touch menu to go back 5 ENTER Enter the...

Страница 12: ...lect sensitivity from 51 to 255 followed by enter touch menu to go back 6 MENU Moves back to step 4 keypad option selection 4 0 Option 0 To Default keypad Touch mute to confirm touch menu to exit 5 MU...

Страница 13: ...u to exit 3 2 Selects Panel and device configuration Select a device number followed by enter touch menu to go back 4 ENTER Select the device you wish to program Selected device is connected select a...

Страница 14: ...to exit 3 3 Selects service provider phone number Service provider phone number is disabled select a new service provider phone number followed by enter touch menu to go back 4 Phone Number Enter the...

Страница 15: ...User 8 Touch MENU MENU to exit Record zone names Speak to record 2 7 seconds recording time MENU 8 Master code 4 1 ENTER TALK ENTER Zone 1 TALK ENTER Zone 2 TALK ENTER Zone 3 TALK ENTER Zone 4 TALK EN...

Страница 16: ...tairs 93 Laundry 131 Stairs 18 Eighteen 56 Driveway 94 Lift 132 Storage 19 Nineteen 57 Duress 95 Light 133 Study 20 Twenty 58 East 96 Living 134 Temperature 21 Thirty 59 emergency 97 location 135 tenn...

Страница 17: ...can be configured as room stations for intercom functionality Two pairs of twisted cable 4 conductors are required for the audio line one pair for audio line A and another for audio line B Maximum to...

Страница 18: ...ad with touch buttons Installation Manual Specifications Voltage 12 VDC regulated Current maximum without voice averaged over 200 ms 140 mA 110 mA Dimensions W H D 80 120 16 mm Operating temperature 0...

Отзывы: