12
NX-181xx NetworX Voice keypad with touch buttons Installation Manual
Table 1: Advanced keypad configuration options
1
Enable keypad tamper switch
5
Status key read message when armed
suppression
2
Entry / exit beeps suppression
6
Enable three second beeps on
emergency keys before alarm
3
Stay arming key suppression
7
Enable Zone Leds 1 – 8 in lieu of partition
Leds 1 - 8
4
Reserved
8
Enable multi partition keypad
4. [7]
Option 7 - Touch sense control (see note below)
Touch sensitivity is ?, select sensitivity from 51 to 255 followed by enter,
touch menu to go back.
5.
[ ? ]
[ENTER]
Enter the required sensitivity level. 51 = more sensitive, 255 = less sensitive
Touch sensitivity is ?, select sensitivity from 51 to 255 followed by enter,
touch menu to go back.
6. [MENU]
Moves back to step 4, keypad option selection.
4.
[ 0 ]
Option 0 - To Default keypad
Touch mute to confirm, touch menu to exit.
5. [MUTE]
Selects to Default keypad.
WARNING:
this will default the keypad you are currently programming.
Automatically Moves back to step 4, keypad option selection
All NX-181xx Voice keypads must be individually addressed for proper security
operation and must have individual room numbers assigned to enable intercom
functionality.
Option 7, touch sense control, is the sensitivity setting for the NX-181xx to go
from idle mode to run mode on the first touch. The setting options are from 51
milliseconds to 255 milliseconds, 51 being more sensitive and 255 being less
sensitive. The default setting is set to 150 milliseconds
Run mode sensitivity is fixed at 50 milliseconds.