Chapter 4: Commands for CLI configuration
rmon
Remote Monitoring
event
Configure an RMON event
<id: 1-65535>
Event entry ID
description
Specify a description of the event
<description>
Event description
log
Generate RMON log when the event fires
trap
Generate SNMP trap when the event fires
<community>
SNMP community string
Default:
None
Usage Guide:
To configure the
Event
of
RMON
Example:
To configure the
Event
(below table)
of
RMON
Switch# configure terminal
Switch (config)#
rmon event 1 log trap IFS description error
sfp temperature-threshold
Command:
sfp temperature-threshold <0-100>
sfp temperature-threshold
Set a lower high temperature threshold for the
secondary temperature alarm in
degrees C.
<0-100>
Specifies the new threshold temperature.
Default:
None
Usage Guide:
To configure the
SFP temperature-threshold
of
sFlow
Example:
To configure the
SFP temperature-threshold
(55 degrees C)
of
sFlow
Switch# configure terminal
Switch (config)#
sfp temperature-threshold 55
snmp-server
Command:
snmp-server
snmp-server
Set SNMP server's configurations
Default:
Enabled
NS4702-24P-4X Managed Switch Command Guide
207