Chapter 4: Commands for CLI configuration
is in 10ms and max is 100. In case 'count' == 0 this is in 1us and
max is 10.000.
dei
Drop Eligible Indicator in case of tagged OAM
.
multi
OAM PDU is transmitted with multicast MAC.
uni
OAM PDU is transmitted with unicast MAC. The MAC is taken from
peer MEP MAC database.
mac
Loop Back unicast MAC to be used in case of LB against MIP.
<Mac : mac_addr>
Loop Back target unicast MAC value
mep-id
Peer MEP-ID for unicast LB. The MAC is taken from peer MEP MAC
database.
<Mepid : uint>
Peer MEP-ID value
Default:
None
Usage Guide:
To configure
Loop Back
of
MEP
.
Example:
To configure
Loop Back
of
MEP 2
as below table
Switch# configure terminal
Switch (config)#
mep 2 lb 1 dei count 10 size 64 interval 100
mep <Instance> lck
Command:
mep <Instance>
lck fr1m | fr1s
mep
Maintenance Entity Point
<Instance>
The MEP instance number.
lck
Locked Signal
fr1m
Frame rate is 1 f/min.
fr1s
Frame rate is 1 f/s.
Default:
1 frame/sec
Usage Guide:
To configure
Locked
Frame Rate
of
MEP
.
Example:
To configure
Locked
Frame Rate (
1 frame/sec
)
of
MEP 2
.
Switch# configure terminal
Switch (config)#
mep 2 lck
Switch (config)#
mep 2 lck fr1s
168
NS4702-24P-4X Managed Switch Command Guide