25
NS3503-16P-4C User Manual
Connect the other end of the cable to the network devices such as printer server, workstation or
router.
Note
: Connection to the Managed Switch requires UTP Category 5 network cabling with RJ45 tips.
For more information, please see the Cabling Specification in Appendix A.
5. Supply power to the Managed Switch.
Connect one end of the power cable to the Managed Switch.
Connect the power plug of the power cable to a standard wall outlet.
When the Managed Switch receives power, the Power LED should remain solid Green.
2.2.2 Rack Mounting
To install the Managed Switch in a 19-inch standard rack:
1. Place the Managed Switch on a hard flat surface, with the front panel positioned towards the front
side.
2. Attach the rack-mount bracket to each side of the Managed Switch with supplied screws attached to
the package.
Figure 2-1-5 shows how to attach brackets to one side of the Managed Switch.
Figure 2-1-5 Attach Brackets to the Managed Switch.
CAUTION: You must use the screws supplied with the mounting brackets. Damage caused to
the parts by using incorrect screws would invalidate the warranty.
3. Secure the brackets tightly.
4. Follow the same steps to attach the second bracket to the opposite side.
5. After the brackets are attached to the Managed Switch, use suitable screws to securely attach the
brackets to the rack, as shown in Figure 2-1-6.
Содержание NS3503-16P-4C
Страница 1: ...NS3503 16P 4C User Manual P N 1073221 REV A ISS 08SEP16 ...
Страница 143: ...141 NS3503 16P 4C User Manual Figure 4 7 3 Multicast Service Figure 4 7 4 Multicast Flooding ...
Страница 302: ...NS3503 16P 4C User Manual 300 The screen in Figure 4 16 5 appears Figure 4 16 5 PoE Schedule Screenshot ...