NS3503-16P-4C User Manual
264
Transmission Interval
The switch is periodically transmitting LLDP frames to its neighbors for having
the network discovery information up-to-date. The interval between each LLDP
frame is determined by the Transmission Interval value. Valid values are
restricted to 5 - 32768 seconds.
Default: 30 seconds
This attribute must comply with the following rule:
(
Transmission Interval * Hold Time Multiplier) ≤65536, and Transmission
Interval >= (4 * Delay Interval)
Holdtime Multiplier
Each LLDP frame contains information about how long the information in the
LLDP frame shall be considered valid. The LLDP information valid period is set
to Holdtime multiplied by Transmission Interval seconds. Valid values are
restricted to 2 - 10 times.
TTL in seconds is based on the following rule:
(Transmission Interval * Holdtime Multiplier) ≤ 65536.
Therefore, the default TTL is 4*30 = 120 seconds.
Reinitialization Delay
When a port is disabled, LLDP is disabled or the switch is rebooted a LLDP
shutdown frame is transmitted to the neighboring units, signaling that the
LLDP information isn't valid anymore. Tx Reinit controls the amount of
seconds between the shutdown frame and a new LLDP initialization. Valid
values are restricted to 1 - 10 seconds.
Transmit Delay
If some configuration is changed (e.g. the IP address) a new LLDP frame is
transmitted, but the time between the LLDP frames will always be at least the
value of Transmit Delay seconds. Transmit Delay cannot be larger than 1/4 of
the Transmission Interval value. Valid values are restricted to 1 - 8192
seconds.
This attribute must comply with the rule:
(4 * Delay Interva
l) ≤Transmission Interval
LLDP-MED Fast Start
Repeat Count
Configures the amount of LLDP MED Fast Start LLDPDUs to transmit during
the activation process of the LLDP-MED Fast Start mechanisim.
Range: 1-10 packets;
Default: 3 packets
The MED Fast Start Count parameter is part of the timer which ensures that
the LLDP-MED Fast Start mechanism is active for the port. LLDP-MED Fast
Start is critical to the timely startup of LLDP, and therefore integral to the rapid
availability of Emergency Call Service.