44
ATS125x/1260 Four-Door/Four-Lift DGP Programming Guide
7-System Options
7-System Options
Menu:
Assign system outputs
The output numbering used in these records is the same as used by the Advisor
Master control panel. Therefore the output numbers used in the Door
Programming menu correspond with the numbers used in the Advisor Master
Installer programming menu 16, output mapping. When assigning output
numbers to these functions, only output numbers associated with the DGP
address can be entered. These ATS125x assignments only activate the outputs
connected to the DGP being programmed.
For a list of available outputs, see
“Short list of available zones and outputs per
Mains fail output number
XX,Mains Fail Output Disabled
*-Dis, 0/p:
This menu specifies the ATS125x output number to be activated when a Mains
Fail condition exists on ATS125x.
Low battery output number
XX,Low Battery Output Disabled
*-Dis, 0/p:
This menu specifies the ATS125x output number to be activated when a Low
Battery condition exists on ATS125x.
Tamper output number
XX,Tamper Output Disabled
*-Dis, 0/p :
This menu specifies the ATS125x output number to be activated when a Cabinet
Tamper or a Siren Fault condition exists on ATS125x.