ATS125x/1260 Four-Door/Four-Lift DGP Programming Guide
11
Number of Cards
Number of cards: 0
Num:
Enter the number of cards in this batch. All cards must be consecutive.
Start User Number
Start User number 0
UN :
Select which user equals the first card.
Alarm Code Prefix Digits
XX, Alarm Code Prefix Digits 0
*-Dis, Digits:
Records the difference between the number of digits in an alarm control code,
and the number of digits in a door control code.
The complete user code is the alarm control code, and the prefix is omitted to
make the door control code.
Examples:
- Prefix digits = 3
- User code = 1234567
Result:
- Prefix = 123, door code = 4567 and the alarm control code = 1234567.
Note:
The Alarm Code Prefix digits entered should be the same as the value
entered for the Alarm Code Prefix in the Advisor Master Installer programming
menu 7. System Options.
RASes to be polled
No RAS’s Are Being Polled
Poll RAS
Enter the RAS addresses of all the RASes connected to the ATS125x local
databus. The display shows the RASes currently recorded.
Keypads (ATS110x, ATS115x), card readers and ATS1170 are polled as RASes.
Polling allows the RAS to transfer data to ATS125x.
The 16 RAS’s that may be polled relate to specific doors on ATS125x, and the
reader’s location if readers are mounted on both sides of the same door.