![Interlogix 60-660-8OM Quik Bridge Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/interlogix/60-660-8om-quik-bridge/60-660-8om-quik-bridge_installation-sheet_2076913007.webp)
P/N 466-2488 • REV A • ISS 02JUL13
7 / 27
Star Button
Option 5 Off
Option 5 On
Not used
Output 2 control
Using the Light and Star button on keyfobs to trigger
outputs
1. To enter programming mode, press *8 followed by 9713.
2. Press 32# to program the RF Receiver module.
3. Enter the transmitter number followed by #. For example,
for transmitter 4 enter 4#.
4. In segment 1 of this location, switch bit 4 and bit 5 On to
enable the Light and the Star button.
5. Press * to save the setting and # to leave the menu.
You must then program the corresponding event in table 8 so
that pressing the button on the keyfob activates the output.
Programming the Quik Bridge®
Table 7 displays the 17 locations that can be programmed on
the Quik Bridge®.
Table 7: Quik Bridge® output locations and segments
Location Segment Description
0 1-4 Programming
code
1 1 Output
1
event
2 Output
1
time
2
1
Output 1 Transmitter selection
2
Output 1 Special Setting
3 1 Output
2
event
2 Output
2
Time
4
1
Output 2 Transmitter selection
2
Output 2 Special Setting
5 1 Output
3
event
2 Output
3
time
6
1
Output 3 Transmitter selection
2
Output 3 Special Setting
7 1 Output
4
event
2 Output
4
time
8
1
Output 4 Transmitter selection
2
Output 4 Special Setting
9 1 Output
5
event
2 Output
5
time
10
1
Output 5 Transmitter selection
2
Output 5 Special Setting
11 1 Output
6
event
2 Output
6
time
12
1
Output 6 Transmitter selection
2
Output 6 Special Setting
13 1 Output
7
event
2 Output
7
time
14
1
Output 7 Transmitter selection
2
Output 7 Special Setting
15 1 Output
8
event
Location Segment Description
2 Output
8
time
16
1
Output 8 Transmitter selection
2
Output 8 Special Setting
17
1
On if Quik Bridge® tamper is enabled
Output event
Enter the number for the event that you wish to program for the
output.
Table 8: Quik Bridge® output events
Data Event
0 Zone
Open
1 Zone
Tamper
2
TX Low Battery
3 TX
Lost
4
TX short supervision fault
5
Clean me fault
6
Zone open or tamper (default value)
7
TX lost or low battery
8
TX lost, low battery or tamper
9
Zone open, TX Lost, low battery or tamper
10 Keyfob
disarm
11 Keyfob
arm
12
Keyfob arm or disarm
13
Keyfob arm stay
14 Keyfob
exit
15 Fob
fire
16 Fob
Medical
17 Keyfob
panic
18
Keyfob aux 1 (Option 4 from ‘Using the 4 button keyfob)
19
Keyfob aux 2 (Option 5 from ‘Using the 4 button keyfob)
20 Receiver
Jam
21
Box tamper (receiver or Quik Bridge®)
22
Receiver communication trouble
23
Receiver communication trouble, box tamper or jam
24 Reserved
25 Reserved
Output time
This can be set from 0-255 in minutes or seconds. The unit is
set in the Special Setting segment.
Special Setting
This can be set in the different bits of the segment.
Bit 1: selection of time in seconds or minutes.
• Turn bit 1 on to time the output in minutes.
• Turn bit 1 off to time the output in seconds.
Bit 2: selection of inverted output.
• Turn bit 2 on to invert output activation.