    Configuring the Device 

15 

 

Column

 

List of

 

I/O 

I/O controller boards of the slave terminals. The characters - + mean: 

 

- + = 1st First I/O controller board for door control is ready for operation. 

 

+ - = 2nd Second I/O controller board (I/O extension board) is ready for operation. 

 

+ + = 1st First I/O controller board and 2nd I/O controller board ready for operation 

 

- - = Slave terminal is operated without I/O controller board 

 

 

6.3  How to apply the configuration 

  Restart the device in order to activate the configured data. 

Changes to the password or the network parameters do not require a restart. 

Restart without deleting data (warm start) 

Select this variant 

– particularly during operation – in order to maintain the stored data. 

Syntax: 

oc -s 

Function: 

This function causes a system reset that corresponds to a warm start via a button or a voltage 

breakdown. The system restarts, no data is deleted. 

Restart with deletion of data (cold start) 

You can use this command during startup of the device. 

Syntax: 

oc -c 

Function: 

Deletes the entire memory (including credentials with booking permission, data for offline 

operation) except the system log book and reboots. The network parameters and the password are 
retained unchanged. 

 

6.4  Preparing to update software 

You require the PuTTY program package for execution. This is a free, open-source SSH, and Rlogin 
client that facilitates remote operation of Unix systems by Windows computers. 

  Install the 

PuTTY 

program package (entire package, version >= 0.62). 

Updates or upgrades are performed using batch files, in which 

C:\Programs\PuTTY

 is specified as 

default installation path for PuTTY. 

The path for the programs 

pscp.exe

 and 

plink.exe

 (part of PuTTY) is defined in the batch file 

setpathvars.bat

. The system password can also be found here. 

  Open 

setpathvars.bat

 in an editor and enter the system password. 

  Adjust the paths for the programs 

pscp.exe

 and 

plink.exe

 if required, for example if you have 

saved PuTTY on a USB stick. 

 

Содержание IF-4735

Страница 1: ......

Страница 2: ......

Страница 3: ...ty for the information in this manual which is subject to change without prior notice Copyright 2019 Version Date April 9 2019 Interflex Datensysteme GmbH Allegion Zettachring 16 D 70567 Stuttgart Ger...

Страница 4: ......

Страница 5: ...electric shock 6 4 2 Electrostatic discharge ESD 6 4 3 Voltage supply 7 4 4 Power supply setting 8 4 5 Redundant power supply 8 5 Interfaces 9 5 1 Bus data cables with slave terminals 9 5 2 Additiona...

Страница 6: ...ii Contents 9 Disposal 19...

Страница 7: ...ocument if you belong to this target group 1 3 Symbols used in this document Warnings warn against hazards that may arise when using the devices described in this document The hazard levels can be ide...

Страница 8: ...ation of the devices Danger to life through explosion Do not use this device in environments exposed to explosion hazards 1 6 All specifications are subject to change without notice All information co...

Страница 9: ...Voltage losses in long cables may impair the function of the connected device We recommend connecting the 5 V and GND lines with two wires each if the cable lengths exceed 50 meters 2 2 Shielded cabl...

Страница 10: ...in 2 4 Encryption of data transfer Transmission credential reader terminal The transmission of data between the credential and the reader terminal is subject to requirements which are constantly chang...

Страница 11: ...ble feed for surface mounted installation Installation Site The device is designed for fixed installation in dry rooms Operation in humid environments is not permitted Maintain a distance of 30 cm to...

Страница 12: ...necessary The device must be connected via an all pole separator to ensure that it can be disconnected completely from the mains power supply if required service maintenance The device must be equipp...

Страница 13: ...250 mA slow blow fuse Power supply is possible with A power supply unit mounting rail or pluggable power supply 18 to 24 VAC DC A PoE device IEE 802 3 of power class 3 up to 13 W 230 V AC optional Th...

Страница 14: ...pin 2 and pin 3 A Power supply via power supply unit 2 Pin 2 B Power supply via Ethernet PoE 3 Pin 3 1 Pin 1 Check the setting of the jumper in order to counteract a redundant power supply 4 5 Redund...

Страница 15: ...inals Connect the RS485 data cables from the slave terminals to screw terminal strip 1 5 2 Additional RS232 interface Connect devices with an RS232 interface as follows Observe the recommended line le...

Страница 16: ...ed in directly on the bottom of the housing 5 4 Connecting an RS232 service device Dialog devices with RS232 interfaces can be connected as shown in the figure below The following settings are require...

Страница 17: ...d from your Interflex system consultant Then the system prompts you to change the password iftc 8D4E56 login root Password You are required to change your password immediately root enforced Changing p...

Страница 18: ...vice and displaying device functions is called OC Task and is available on the device OC Task contains a number of commands that are used for administrative purposes To access OC task the device must...

Страница 19: ...ddress 172 18 20 110 Gateway 172 18 70 1 Netmask 255 255 0 0 Port number 2001 hostname IF xxxx Confirm other settings e g Gateway Netmask etc that are not to be changed by pressing the Enter key Pleas...

Страница 20: ...0 IFx 2 04 6 b OL 2x20 NF PSCR P 2 1 B 2 0 16 3 F 15 0 IFx 2 04 6 b NF PSCR P Column List of B 3 bus interfaces with the terminal distribution e g the factory configured default distribution of 6 4 an...

Страница 21: ...ed Restart with deletion of data cold start You can use this command during startup of the device Syntax oc c Function Deletes the entire memory including credentials with booking permission data for...

Страница 22: ...ense tcdiag bat Gathers diagnostic information on the device in a file which is saved in the same folder as the batch file tctermfwup bat Firmware update via the network of the controller or recording...

Страница 23: ...rial number is 711229 The new file is an xml file Performing upgrade Start cmd exe and run batch file File name Command tclicence bat tclicence bat License file IP address controller The license is au...

Страница 24: ...100 Mb RS232 interface up to 19200 baud RS422 or RS485 interface up to 19200 baud Interfaces to terminals slaves RS485 interface Service interfaces SSH RS232 interface with 115200 baud I O interfaces...

Страница 25: ...program packages This product uses program packages that are subject to Open Source License Terms e g GNU GPL License Version 2 Upon request and for a charge no more than your cost of physically perfo...

Отзывы: