background image

 

System Overview 

 

After receiving the data, the host system evaluates it and reacts depending on the data received. For 
booking data, the IF-60x0 system sends back a positive or negative booking response, for example. 
Depending on the booking response, access is either permitted or denied. 

The IF-60x0 system can also actuate relays or trigger an alarm if certain events occur. All booking data 
and events of the connected terminals are stored in the memory of the 

IF-4735

 device. 

Offline mode 

If there is no transfer of data between the 

IF-4735

 device and the parent host system (e.g. the IF-60x0 

system), the device will automatically switch to offline mode. There, it records all bookings and events 
and autonomously makes decisions based on configured conditions. 

In the event of a positive decision, a booking response and/or a signal for activating an output relay, for 
example, are transmitted to the booking location. If the decision is negative, the reason for the booking 
rejection is transmitted. 

All bookings and status changes recorded in offline mode are stored in the device, together with a special 
remark. The 

IF-4735

 device transmits this data to the parent host system once an online connection has 

been established again. 

 

2.4  Encryption of data transfer 

Transmission, credential <-> reader/terminal 

The transmission of data between the credential and the reader/terminal is subject to requirements which 
are constantly changing. Interflex is always always up-to-date in supporting the current credential and 
reader technologies. 

Transmission, reader/terminal <-> controller 

The data transmission between terminal and controller takes place via an RS485 two-wire line, which is 
installed in the secured area. You can encrypt the data transmission, by using the terminal controllers of 
the IF-4xxx series, the master terminals of the IF-5xxx series and the slave terminals of the IF-8xx series. 

The controllers are equipped with up to 3 bus systems that can be used to connect several slave 
terminals. Data encryption can be activated or deactivated for each connected slave terminal individually. 
You can configure this setting when starting up the controller. Mixed operation of encrypted and 
non-encrypted transmission on the same bus is possible. 

For this purpose, the devices must be equipped with a minimum software version: 

 

Controller: Version V7.13.05 or higher. 

 

IF-8xx slave terminals: Version 7.ba or higher. 

Transmission, controller <-> host system 

You can activate and deactivate the encryption for this data link in the host system. You will find details in 
the documentation of the host system. 

See also 

Setting interfaces, booking memory and encryption .............................................................. 13 

 

 

Содержание IF-4735

Страница 1: ......

Страница 2: ......

Страница 3: ...ty for the information in this manual which is subject to change without prior notice Copyright 2019 Version Date April 9 2019 Interflex Datensysteme GmbH Allegion Zettachring 16 D 70567 Stuttgart Ger...

Страница 4: ......

Страница 5: ...electric shock 6 4 2 Electrostatic discharge ESD 6 4 3 Voltage supply 7 4 4 Power supply setting 8 4 5 Redundant power supply 8 5 Interfaces 9 5 1 Bus data cables with slave terminals 9 5 2 Additiona...

Страница 6: ...ii Contents 9 Disposal 19...

Страница 7: ...ocument if you belong to this target group 1 3 Symbols used in this document Warnings warn against hazards that may arise when using the devices described in this document The hazard levels can be ide...

Страница 8: ...ation of the devices Danger to life through explosion Do not use this device in environments exposed to explosion hazards 1 6 All specifications are subject to change without notice All information co...

Страница 9: ...Voltage losses in long cables may impair the function of the connected device We recommend connecting the 5 V and GND lines with two wires each if the cable lengths exceed 50 meters 2 2 Shielded cabl...

Страница 10: ...in 2 4 Encryption of data transfer Transmission credential reader terminal The transmission of data between the credential and the reader terminal is subject to requirements which are constantly chang...

Страница 11: ...ble feed for surface mounted installation Installation Site The device is designed for fixed installation in dry rooms Operation in humid environments is not permitted Maintain a distance of 30 cm to...

Страница 12: ...necessary The device must be connected via an all pole separator to ensure that it can be disconnected completely from the mains power supply if required service maintenance The device must be equipp...

Страница 13: ...250 mA slow blow fuse Power supply is possible with A power supply unit mounting rail or pluggable power supply 18 to 24 VAC DC A PoE device IEE 802 3 of power class 3 up to 13 W 230 V AC optional Th...

Страница 14: ...pin 2 and pin 3 A Power supply via power supply unit 2 Pin 2 B Power supply via Ethernet PoE 3 Pin 3 1 Pin 1 Check the setting of the jumper in order to counteract a redundant power supply 4 5 Redund...

Страница 15: ...inals Connect the RS485 data cables from the slave terminals to screw terminal strip 1 5 2 Additional RS232 interface Connect devices with an RS232 interface as follows Observe the recommended line le...

Страница 16: ...ed in directly on the bottom of the housing 5 4 Connecting an RS232 service device Dialog devices with RS232 interfaces can be connected as shown in the figure below The following settings are require...

Страница 17: ...d from your Interflex system consultant Then the system prompts you to change the password iftc 8D4E56 login root Password You are required to change your password immediately root enforced Changing p...

Страница 18: ...vice and displaying device functions is called OC Task and is available on the device OC Task contains a number of commands that are used for administrative purposes To access OC task the device must...

Страница 19: ...ddress 172 18 20 110 Gateway 172 18 70 1 Netmask 255 255 0 0 Port number 2001 hostname IF xxxx Confirm other settings e g Gateway Netmask etc that are not to be changed by pressing the Enter key Pleas...

Страница 20: ...0 IFx 2 04 6 b OL 2x20 NF PSCR P 2 1 B 2 0 16 3 F 15 0 IFx 2 04 6 b NF PSCR P Column List of B 3 bus interfaces with the terminal distribution e g the factory configured default distribution of 6 4 an...

Страница 21: ...ed Restart with deletion of data cold start You can use this command during startup of the device Syntax oc c Function Deletes the entire memory including credentials with booking permission data for...

Страница 22: ...ense tcdiag bat Gathers diagnostic information on the device in a file which is saved in the same folder as the batch file tctermfwup bat Firmware update via the network of the controller or recording...

Страница 23: ...rial number is 711229 The new file is an xml file Performing upgrade Start cmd exe and run batch file File name Command tclicence bat tclicence bat License file IP address controller The license is au...

Страница 24: ...100 Mb RS232 interface up to 19200 baud RS422 or RS485 interface up to 19200 baud Interfaces to terminals slaves RS485 interface Service interfaces SSH RS232 interface with 115200 baud I O interfaces...

Страница 25: ...program packages This product uses program packages that are subject to Open Source License Terms e g GNU GPL License Version 2 Upon request and for a charge no more than your cost of physically perfo...

Отзывы: