CONNECTIONS

Fittings

 

ƒ

Install a female coupler to the hose . The female coupler 

will connect to the quick release that fits the tool .

Filter-Regulator-Lubricator

 

ƒ

Never connect tool to pressure that potentially exceeds 

150 psi or 10 .34 bar .

 

ƒ

Filter-regulator-lubricator units supply an optimum 

condition for the tool and extend the tool life . These units 

should always be used .

Filter
 

ƒ

The filter removes moisture and dirt mixed in compressed 

air .

 

ƒ

Keep the filter clean by maintaining tool regularly .

 

ƒ

Drain daily .

Regulator

 

ƒ

The regulator controls the operating pressure for safe 

operation of the tool .

 

ƒ

Inspect the regulator before operation to be sure it 

operates properly .

 

ƒ

Use a regulator with a pressure range of 0 - 110 psi .

Lubricator

 

ƒ

The lubricator supplies an oil mist to the tool .

 

ƒ

Inspect the lubricator before operation to be sure the 

supply of lubricant is adequate .

 

ƒ

If an inline lubricator is not available, supply 3 to 5 drops 

of INTERCHANGE pneumatic tool lubricant into the air 

plug on the tool twice a day .

Air Hose

 

ƒ

Air hose must be professional grade and have a minimum 

working pressure rating of 150 psi ﹙10 .3 bar﹚ or 150% 

of the maximum pressure produced in the system, 

whichever is higher .

1

1

2

2

3

3

OpERATING THE TOOL

Содержание SGSW5016

Страница 1: ...fully read through this OPERATOR S MANUAL to ensure efficient safe operation It is rec ommended that the MANUAL be kept readily available as an important reference when using this tool Ask for Genuine...

Страница 2: ...ation 5 Accessories 5 Safety Information Safety Instructions 6 9 Employer s Responsibilities 9 Operating the Stapler Staple Loading 10 Methods of Operation 10 Adjusting the Stapling Depth 11 Operation...

Страница 3: ...URY Most accidents that result from the operation and maintenance of staplers are caused by the failure to observe basic safety rules or precautions An accident can often be avoided by recognizing a p...

Страница 4: ...taple Length 5 8 to 2 16 to 50mm Recommended Operating Pressure 70 to 120 psi 5 to 8 5 kgs Applications Wire lathing Staple Specifications FASTENERS 16 ga 063 x 055 1 60 x 1 40mm 5 8 to 2 16 to 50mm 1...

Страница 5: ...de Crown Stapler Drives 15 16 Crown Staples 5 8 to 2 16 to 50mm Model No SGSW5016 Item No 64415 5 Interchange Brands Operator s Manual Accessories STANDARD ACCESSORIES Parts Identification 1 Eye Prote...

Страница 6: ...ars from loud noise Wear head protection to protect your head from flying objects 3 KEEP FACE HANDS AND FEET AWAY FROM FIRING HEAD AT ALL TIMES Never place your face hands or feet near the firing head...

Страница 7: ...h lever is operating properly otherwise the stapler could drive a fastener unexpectedly Do not tamper with or remove the safety push lever otherwise the safety push lever becomes inoperable 16 CHOICE...

Страница 8: ...the fastener could fly free and hit someone 27 NEVER DRIVE FASTENERS FROM BOTH SIDES OF A WALL AT THE SAME TIME The fasteners could be driven into and through the wall and hit a person on the opposite...

Страница 9: ...to tool malfunction and resulting injuries Only authorized service personnel should repair the stapler 36 NEVER MODIFY OR ALTER A STAPLER Doing so may cause it to malfunction and personal injuries ma...

Страница 10: ...could result in accidental firing of the tool 2 1 STAPLE LOADING Keep stapler pointed downward Pull the staple feeder backward until it latches Place the staple strip onto the rail of the magazine Mak...

Страница 11: ...ool out of direct sunlight as excessive heat can deteriorate bumpers o rings and other rubber parts resulting in increased maintenance OPERATING THE TOOL DRIVING DEPTH ADJUSTMENT Depth drive adjustmen...

Страница 12: ...ure is 70 to 120 psi 5 to 8 5 kgs Maximum permissible operating pressure is 120 psi Select the operating pressure within this range for the best fastener performance The fastener length and thickness...

Страница 13: ...ir Keep the filter clean by maintaining tool regularly Drain daily Regulator The regulator controls the operating pressure for safe operation of the tool Inspect the regulator before operation to be s...

Страница 14: ...2 Adjust the air pressure to 70 psi Connect the air hose Do not load any staples in the stapler THE STAPLER MUST NOT LEAK AIR Hold the stapler downward and pull the trigger THE STAPLER MUST NOT LEAK A...

Страница 15: ...open blade guide 4 Remove the jammed staple with a slotted head screwdriver 5 Close blade guide and latch 6 In case of frequent jams contact an authorized service center A qualified person should per...

Страница 16: ...eners jam in tool Solution Check for correct fastener Check proper air pressure Check magazine and feeder operation Replace piston driver assembly Problem Intermittent feed Solution Use recommended fa...

Страница 17: ...arts Drawing Schematics Parts List Parts Kits 1 3 5 6 7 10 11 12 13 14 15 16 17 18 14 19 20 22 9 8 SGSW5016 2 4 14 21 23 27 34 35 36 38 39 40 26 3 30 31 32 33 29 42 44 55 53 52 51 49 50 70 69 75 85 84...

Страница 18: ...X2 4 63 621440 SPRING 19 110570 CYLINDER RING 64 324040 STRAIGHT PIN 20 511630 O RING 47X2 4 65 420160 PIN CAP B 21 323990 WASHER 66 324300 NUT 22 410910 BUMPER 67 310880 COVER A 23 110580 BODY 68 640...

Страница 19: ...98117 SGSW5016K7 Kit 7 Safety Kit for SGSW5016 98118 SGSW5016K8 Kit 8 Feeder Kit for SGSW5016 WARNING Always follow the tool manufacturer s safety and maintenance instructions Always wear safety glass...

Страница 20: ...from this warranty 4 Labor charges maintenance or loss damage and repairs resulting from improper operation are not covered by this warranty This warranty will be honored only if 1 Clean dry regulate...

Отзывы: