MODEL: LS 6/6, LS 12/2, LS 12/6, LS 24/3 
LS 24/5, LS 36/3, LS 48/5, EX 24/3

Full Wave Phase Controlled Rectification

CONTROL:

Voltage limited to 2.4 Volts/Cell
Current limited to AMP rating Mean D.C.
Finish voltage 2.3 Volts/Cell 
Proportional Timed Cyclic Charge Stage
Flashing Yellow LED-to Show 80% State of 
Charge

PROTECTION:

Electronic reverse polarity
Short circuit shutdown
Low voltage start
Optional: Temperature compensation

DIMENSIONS: Lineage Series

6.5" WIDE, 6.0" FRONT TO BACK, 5.25" HIGH

DIMENSIONS: EX Series 
3.5 WIDE, 3.25 FRONT TO BACK, 6.0 HIGH

LISTED

              CONFORMS TO 
                      U.L. 1236

1. IMPORTANT SAVE THESE INSTRUCTIONS-- This 
manual contains important safety and operating 
instructions for all INTERACTER battery chargers.

2. Before using this battery charger, read all 
instructions and cautionary markings on (1) the battery 
charger, (2) the battery, (3) product using the battery.

3.CAUTION--To reduce risk of injury, charge only lead 
acid, maintenance free or flooded lead acid type 
rechargable batteries. Other types of batteries may 
burst causing personal injury and damage.

4. Do not expose charger to rain or snow.

5. Use of an attachment not recommended or sold by 
the battery charger manufacturer may result in a risk of 
fire, electric shock or injury to person.

6. To reduce risk of damage to electric plug and cord, 
pull by plug rather than cord when disconnecting 
charger.

7. Make sure cord is located so that it will not be 
stepped on, tripped over or otherwise subjected to 
damage or stress.

8. An extension cord should not be used unless 
absolutely necessary. Use of improper extension cord 
could result in risk of fire and electrical shock. If an 
extension cord must be used, make sure:

a.

That pins on plug of the extension cord are the 
same number, size and shape as those of the 
plug on the charger.

   b.     That the extension cord is properly wired 

3

LINEAGE and EX SERIES 

SPECIFICATIONS

IMPORTANT SAFETY 

INSTRUCTIONS

Содержание Commercial Series

Страница 1: ... Current Constant Voltage Proportionally timed system used in all Interacter models provides fast charging and optimal timing over a wide range of battery sizes and depths of discharge STANDARD FEATURES OF ALL INTERACTER CHARGERS LINEAGE SERIES LS MODELS are the most cost effective series and are available for 6 12 24 36 and 48 volt batteries rated at up to 6 amps EX SERIES EX Utilizes the LS cont...

Страница 2: ...y Type Switch DIMENSIONS Inches 12 0 WIDE 7 0 FRONT TO BACK 7 0 HIGH MODEL PS 12 5 INPUT 117 Volts AC 60Hz 110 VA OUTPUT 5 Amps DC 12 Volts MODEL PS 12 10 INPUT 117 Volts AC 60Hz 220 VA OUTPUT 10 Amps DC 12 Volts MODEL PS 24 5 INPUT 117 Volts AC 60Hz 200 VA OUTPUT 5 Amps DC 24 Volts MODEL PS 24 8 INPUT 117 Volts AC 60Hz 320 VA OUTPUT 8 Amps DC 24 Volts Optional Export AC Input Ratings 100v 50Hz AC...

Страница 3: ...sing the battery 3 CAUTION To reduce risk of injury charge only lead acid maintenance free or flooded lead acid type rechargable batteries Other types of batteries may burst causing personal injury and damage 4 Do not expose charger to rain or snow 5 Use of an attachment not recommended or sold by the battery charger manufacturer may result in a risk of fire electric shock or injury to person 6 To...

Страница 4: ...engine 1 Someone should be within range of your voice or close enough to come to your aid when you work near a lead acid battery 2 Have plenty of fresh water and soap nearby in case battery acid contacts skin clothing or eyes 3 Wear complete eye protection and clothing protection Avoid touching eyes while working near battery 4 If battery acid contacts skin or clothing wash immediately with soap a...

Страница 5: ...nnect and disconnect DC output only after removing AC cord from electric outlet Never allow clips to touch each other 2 Attach clips to battery posts and twist or rock back and forth several times to make a good connection This tends to keep clips from slipping off terminals and helps to reduce risk of sparking FOLLOW THESE STEPS WHEN BATTERY IS INSTALLED IN VEHICLE A SPARK NEAR A BATTERY MAY CAUS...

Страница 6: ...cian Improper connection can result in a risk of an electrical shock This battery charger is for use on a nominal 117 volt AC circuit and has a grounded plug that looks like the plug illustrated in sketch A A temporary adapter which looks like the adapter illustrated in sketches B C may be used to connect this plug to a two pole receptacle as shown in sketch B if a properly grounded outlet is not ...

Страница 7: ...LED Amp Meter At the start of charge if the battery is normally discharged all 4 RED LED s will be on and will go out in sequence as the charge current drops When the last RED LED goes off the internal proportional timer will start the GREEN LED will show proportional to the time of the constant current time T 2 1hr 7 If the battery voltage is less than half a volt the battery is considered very h...

Страница 8: ...attery posts to ensure good connection GREEN READY LIGHT DOES NOT APPEAR AFTER 18 HOURS 3 The Microprocessor Control can indicate a problem with the battery If the battery has not reached the First Stage of the Operation within 18 hours the charger may determine that a problem exists within the battery or the battery is too big for the charger s output rating The OVERRIDE TIMER FUNCTION is shown b...

Страница 9: ...ccording to these instructions For service call or write the manufacturer CAUTION RISK OF ELECTRICAL SHOCK Do not attempt any servicing unless you are authorized and qualified to do so a CONSERVER CES INSTRUCTIONS CE MANUEL CONTIENT DES INSTRUCTIONS IMPORTANTES CONCERNANT LA SECURITE ET LE FONCTIONNEMENT b IL EST DANGEREUX DE TRAVAILLER A PROXIMITE D UNE BATTERIE AU PLOMB LES BATTERIES PRODUISENT ...

Страница 10: ... LAS PINCES DU CORDON C C S ASSURER QUE LES PINCES NE SE TOUCHENT PAS l SUIVRE LES ETAPES SUIVANTES LORSQUE LA BATTERIE SE TROUVE DANS LE VEHICULE UNE ETINCELLE PRES DE LA BATTERIE POURAIT PROVOQUER L EXPLOSION DE CETTE DERNIERRE POUR REDUIRE LE RISQUE D ETINCELLE A PROXIMITE DE LA BATTERIE i PLACER LES CORDONS C A ET C C DE MANIERE A EVITER QU ILS SOIENT ENDOMMAGES PAR LE CAPOT UNE PORTIERE OU LE...

Страница 11: ... For units fitted with wall mounting brackets the battery charger should be securely attached to an indoor dry vertical surface using four brass 8 X 1 round head wood screws not supplied The unit must be mounted vertically with the wires at the bottom in a location where airflow forcooling is unobstructed for six inches above and three inches to each side of the battery charger MODEL EX 2402 evalu...

Страница 12: ...zed by the manufacturer accidents negligence or commercial use voids this warranty Parts subject to normal wear and tear are not covered by this warranty Should a unit be returned for a cause not covered by this warranty or without the items specified above any repairs handling or testing will be made at the owner s expense and risk ALL IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO ANY IMPLIED W...

Отзывы: