12
SC-9216R
SPEAKER LINE CHECKER
Display
Display
The following display information is representative of the display information on the front panel of the SC-
9216R. It is provided to inform the system operator of various system settings, status, and when system servicing
is recommended. Each display is intended to be as informative as the limited space will allow. A brief
description of each display is provided below along with a display number. This number corresponds to the
associated text in the operational instructions in this manual.
1. Product Description
This screen flashes three times during when the AC mains is switched on to
identify the product and its capabilities. The SC-9216R is capable of
checking 16 channels and may be expanded to a total of 32 channels with
the use of the SC-9116R
2. Test Interval
This screen is the default screen. It identifies the time span between automatic
tests and the time remaining until the next automatic test occurs. The factory
default time is 1 hour. Operators may change this setting to a minimum of 1
minute or maximum of 24 hours. A test may be conducted at any time without
waiting for the next scheduled as described in the manual tests section.
3. Test Interval Set
This screen is used only for changing the time span between automatic tests.
The display indicates the current setting as “OLD”. The new setting is
established by navigating the four cursor buttons on the front of the SC-
9216R. The Left and Right buttons move the position of the cursor to the
desired digit. The Up and Down buttons change the value of the digit
selected. One minute (0:01:00) is the minimum time, twenty four hours (24:00:00) is the maximum time. The
factory default is one hour (01:00:00)
4. Memory clear
Depressing the ENTER button when this screen is displayed will erase all
previously stored settings and return to the defaults set by the factory. This
action will require all new references to be stored into the product.
16 Ch. Speaker
Line Checker
or 32 Ch. with
SC-9116R
Test Interval
1:00:00
NEXT TEST IN
0:59:59
Test Interval
OLD 1:00:00
NEW 1:00:00
1 min. to 24 hrs.
Press ENTER to
CLEAR MEMORY.
New Settings
will be required.