background image

8

SC-9216R

SPEAKER LINE CHECKER

9. Depress the OP MODE button several times to navigate to the TEST INTERVAL SET display. Set a new Test

Interval using the four CURSOR buttons and then depress ENTER. The new Test Interval time will be indicated
on the display. The display will then change to reveal the time remaining until the next test. Maximum time is
24 hours, minimum time is 1 minute. The default setting is 1 hour.

10. The SC-9216R will conduct a test automatically according to the Test Interval setting as indicated on the

display screen. The test will result in either “normal” or “fault found”. If all channels tested normally, the
product will display the Test Interval screen and begin the count down until the next test. If one or more faults
were identified in the test, these will be indicated in the display as described in step 11.

11. The Fault (or problem) associated with any channel(s) which failed the test will be indicated in the display

along with a recommendation to have the channel(s) serviced. This Fault display mode will remain in effect
until the next automatic test sequence or until the Op Mode button is depressed. All displays except for the
fault display will eventually return to the test Interval display.

- ROUTINE OPERATION

Operating an existing system.
1. Switch ON the AC mains to the SC-9216R using the POWER button on the front panel. The display will flash

the product description three times and then indicate the time remaining until the next automatic test. The SC-
9216R will function properly with the amplifier(s) and/or other system components OFF or ON. Other system
electronics may be switched ON and the sound system will operate normally whether or not the SC-9216R is
switched ON.

2. A clicking sound may be heard as a test is conducted on each channel. This sound is normal (caused by

relays sequencing) and is not a cause for concern.

3. If all channels test normally the display will indicate the time remaining until the next test.
4. If a fault is detected on one or more channels the Fault indicator will illuminate, the Buzzer will sound, and the

display will indicate “Fault Found”. The Buzzer will sound continuously for the remainder of the test and then
will cycle on/off repeatedly once the test is complete. At this time the BUZZER may be switched off using the
BUZZER OFF button.

5. The Fault (or problem) associated with any channel(s) which failed the test will be indicated in the display

along with a recommendation to have the channel(s) serviced. This Fault display mode will remain in affect
until either the next automatic test or until the Op Mode button is depressed. All displays except for the fault
display will eventually return to the display that indicates the time remaining until the next test.

6. Steps 2-4 will repeat automatically according to how the Time Interval has been set. See step 8 in the Initial

Operation instructions to change the Time Interval.

7. The SC-9216R may be switched OFF (and back ON again) at anytime without affecting system performance.

- ADVANCED OPERATION

This section assumes and requires that the reader clearly understands both the Initial Operation and the Routine
Operation instruction.

SC-9216R Advanced Overview
Reference Parameters
The SC-9216R has the ability to “look” at a speaker system (or load), check the impedance on the line, and store
that impedance as a reference value to compare against future impedance tests. The reference impedance may
not agree with other “outside” impedance measurements or calculations for a variety of reasons, but most
importantly because the SC-9216R conducts the measurements at approximately 15kHz which normally is not
the frequency used to determine the impedance of a loudspeaker. The test voltage is 5 Volts and of a duration of

Содержание SC-9216R

Страница 1: ...SC 9216R Speaker Line Checker SC SPEAKER LINE CHECKER 9216R ENTER BUZZER OFF FAULT POWER OFF ON OP MODE UP CURSOR DOWN LEFT RIGHT B370031 OC03 OC03 021 0 ...

Страница 2: ... 2 Installation Environment 3 Important Safety Instructions 3 Description 4 Features 4 Front Panel 5 Rear Panel 6 Operation 7 Tests 10 Applications 16 Block Diagram 19 Specifications 20 Service Procedures 21 Schematic 21 Parts List 21 Variations and Options 21 Warranty 21 ...

Страница 3: ...d with liquids such vases shall be placed on the apparatus Worded WARNING FOR YOUR PROTECTION PLEASE READ THE FOLLOWING WATER AND MOISTURE Unit should not be used near water e g near a bathtub washbowl kitchen sink laundry tub in a wet basement or near a swimming pool etc Care should be taken so than objects do not fall and liquids are not spilled into the enclosure through openings This symbol is...

Страница 4: ...the SC 9216R and the system amplifier s 2 Terminate the inputs and outputs of the SC 9216R 3 Switch ON the AC mains to the SC 9216R Other components may be switched ON as well 4 Select which channels will be tested or omitted from testing 5 Clear all previously stored settings 6 Create new reference values for channels being tested 7 Create a new test interval if desired 1 hour default 8 Wait for ...

Страница 5: ...third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by ...

Страница 6: ...s complete loudspeaker system status for up to 32 channels Operates on AC mains or DC power Description Description The SC 9216R is a 16 channel speaker line tester that may be expanded to 32 channels with the use of the SC9116R It automatically performs tests on speaker lines and can indicate fault conditions audibly or via the display screen The product is easy to operate and has many useful cap...

Страница 7: ...or more faults were identified during the most recent test 5 POWER LED This confirms that the AC Mains power has been switched ON or OFF 6 ENTER BUTTON This button is only active during certain operations as needed to activate operational commands 7 BUZZER OFF BUTTON This button will stop the fault indicator buzzer sound until it reactivates due to a fault condition during a subsequent test 8 POWE...

Страница 8: ...VDC TERMINALS These terminals are for 24VDC power input 7 AMP IN SPEAKER LINE CONNECTION TERMINAL These terminals are provided for connection with the speaker level input output signals 8 CHANNEL SELECT SWITCH The position of these switches determines whether a specific channel will be included in the testing process TO SC 9116R CHECKING CHANNEL DC 24V INPUT 11W EXT IN CHECK OUT 1 2 FAULT OUT 16 9...

Страница 9: ...annel will be checked 5 Switch ON the AC mains to the SC 9216R The display will flash the product description three times and then indicate the Test Interval and time remaining until the next automatic test In the event that an automatic test occurs before step 6 see 5A 5a Do not interrupt a test If the test completes without triggering a fault display or buzzer sound proceed with step 6 If a faul...

Страница 10: ... each channel This sound is normal caused by relays sequencing and is not a cause for concern 3 If all channels test normally the display will indicate the time remaining until the next test 4 If a fault is detected on one or more channels the Fault indicator will illuminate the Buzzer will sound and the display will indicate Fault Found The Buzzer will sound continuously for the remainder of the ...

Страница 11: ...tors Use of speaker attenuators or volume controls in a speaker line will result in a change in impedance with changes in attenuation settings This impedance change may result in a Fault indication on the SC 9216R and the SC 9116R expander The following actions are recommended when a speaker attenuator is on the line These instructions apply to channels in which changes to an attenuator is permitt...

Страница 12: ... 75 to 85 of reference value Line Short 75 of reference value REMOTE CAPABILITIES Remote interrupt EXT IN The SC 9216R includes a provision for contact closure at a remote location to pause operation Normal operation resumes when the contact closure is released Remote fault indicator FAULT OUT 1 2 The SC 9216R includes a provision for a fault indicator at a remote location Remote fault indicators ...

Страница 13: ...www inter m com 4 3 2 1 5 6 7 8 ON 4 3 2 1 5 6 7 8 ON C H C H C H C H C H C H C H C H C H C H C H C H C H C H C H C H CH 1 CH 2 CH 3 CH 4 CH 5 CH 6 CH 7 CH 8 C H C H C H C H C H C H C H C H C H C H C H C H C H C H C H C H CH 9 CH 10 CH 11 CH 12 CH 13 CH 14 CH 15 CH 16 TO SPEAKER FROM AMP AC INPUT 230V 50Hz 11W FUSE T250mAL 250V S N OC03 OC03 021 0 MADE IN KOREA MODEL NO SC 9216R SPEAKER LINE CHECK...

Страница 14: ... default time is 1 hour Operators may change this setting to a minimum of 1 minute or maximum of 24 hours A test may be conducted at any time without waiting for the next scheduled as described in the manual tests section 3 Test Interval Set This screen is used only for changing the time span between automatic tests The display indicates the current setting as OLD The new setting is established by...

Страница 15: ...ocess is described in the Advanced Operation section of this manual Selecting 5 1 is generally suitable 7 1 of 5 Fault Found The FAULT FOUND display will indicate which channel has any one of five different types of faults with a recommendation to have the system serviced The failure criteria are listed with the failure modes in the specifications section and the failure criteria section of this m...

Страница 16: ...hed back to the operating position This is described in greater detail in the Remote section of this manual 10 1 of 4 All Check ALL CHECK will manually cause a test to occur without waiting for the next scheduled automatic test One of the four system configurations 4 1 4 2 4 3 4 4 must be selected though in most applications it does not matter which one is used The selection process is described i...

Страница 17: ...e four system configurations 5 1 5 2 5 3 5 4 must be selected though in most applications it does not matter which one is used The selection process is described in the Advanced Operation section of this manual Selecting 5 1 is generally suitable 10 3 10 4 To test ALL CHANNELS press ENTER Spk Z x 70V To test ALL CHANNELS press ENTER Spk Z x 100V 11 1 11 2 To test CHANNEL XX press ENTER Spk W x 70V...

Страница 18: ... C H CH 9 CH 10 CH 11 CH 12 CH 13 CH 14 CH 15 CH 16 S N www inter m com OC03 OC03 021 0 TO SPEAKER FROM AMP DC OUT DC IN NORMAL RELAY CH 1 CH 2 CH 3 CH 4 CH 5 CH 6 CH 7 CH 8 AMP IN CH 9 CH 10 CH 11 CH 12 CH 13 CH 14 CH 15 CH 16 EM RELAY SPEAKER OUT 1 8 SPEAKER OUT 9 16 HOT COM CH 16 CH 15 CH 14 CH 13 CH 8 CH 7 CH 6 CH 5 RELAYGROUP SPEAKER IN CH1 CH8 SPEAKER IN CH9 CH16 CH 12 CH 11 CH 10 CH 9 CH 4 ...

Страница 19: ... H C H CH 9 CH 10 CH 11 CH 12 CH 13 CH 14 CH 15 CH 16 S N www inter m com OC03 OC03 021 0 TO SPEAKER FROM AMP DC OUT DC IN NORMAL RELAY CH 1 CH 2 CH 3 CH 4 CH 5 CH 6 CH 7 CH 8 AMP IN CH 9 CH 10 CH 11 CH 12 CH 13 CH 14 CH 15 CH 16 EM RELAY SPEAKER OUT 1 8 SPEAKER OUT 9 16 HOT COM CH 16 CH 15 CH 14 CH 13 CH 8 CH 7 CH 6 CH 5 RELAYGROUP SPEAKER IN CH1 CH8 SPEAKER IN CH9 CH16 CH 12 CH 11 CH 10 CH 9 CH ...

Страница 20: ...P IN 2 ALL GROUP 1 GROUP 2 TIMER REMOTE S N 4 3 2 1 5 6 7 8 ON 4 3 2 1 5 6 7 8 ON CHECKING CHANNEL 16 9 C H C H C H C H C H C H C H C H C H C H C H C H C H C H C H C H C H C H C H C H C H C H C H C H 8 1 TO SC 9216R CH 1 CH 2 CH 3 CH 4 CH 5 CH 6 CH 7 CH 8 C H C H C H C H C H C H C H C H CH 9 CH 10 CH 11 CH 12 CH 13 CH 14 CH 15 CH 16 S N www inter m com OC03 OC03 021 0 TO SPEAKER FROM AMP REMOTE SW...

Страница 21: ...19 SC 9216R SPEAKER LINE CHECKER Block Diagram Block Diagram ...

Страница 22: ...85 of reference value Line Short 75 of reference value Test Duration per channel 100msec Test Interval selectable 1 minute to 24 hours Number of Channels 16 Test Frequency 15kHz Test Voltage 5VAC Operating Temperature 5 C 40 C GENERAL Power Source 100 120VAC or 220 240VAC 50 60Hz DC 24V Supplied AC mains transformer depends on country requirements Power Consumption 11W Weight 5 7kg 12 6lb Dimensio...

Страница 23: ...ntacting your warranty provider Variations and Options Variations and Options Variations Products supplied through legitimate sources are compatible with local AC power requirements Options No optional items are available for this product Warranty Warranty Warranty terms and conditions vary by country and may not be the same for all products Terms and conditions of warranty for a given product may...

Страница 24: ...y but rather a global company that is truly international in scope with factories and offices in Korea and China and sales and marketing operations located in Japan Europe and the U S A With more than 850 employees around the globe Inter M is well poised for further growth and expansion INTER M AMERICAS INC 1 EAST BEACON LIGHT LANE CHESTER PA USA 19013 4409 TEL 610 874 8870 FAX 610 874 8890 Home P...

Отзывы: