Inter-m PCT-610 Скачать руководство пользователя страница 4

PUBLIC ADDRESS AMPLIFIER  

2

PCT-610/620

Installation

Installation

Environment

Never place this product in an environment which could alter its performance or reduce its service life. Such
environments usually include high levels of heat, dust, moisture, and vibration.

Important Safety Instructions

1.  Read these instructions.
2.  Keep these instructions.
3.  Heed all warnings.
4.  Follow all instructions.
5.  Do not use this apparatus near water.
6.  Clean only with dry cloth.
7.  Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8.  Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including

amplifiers) that produce heat.

9.  Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades

with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide
blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult
an electrician for replacement of the obsolete outlet.

10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and

the point where they exit from the apparatus.

11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus.

When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the

apparatus has been damaged in any way, such as power-supply cord or plug is
damaged, liquid has been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not operate normally, or has
been dropped.

Unpacking

Unpacking

Although your PCT-610 / 620 is neither complicated nor difficult to operate, we recommend you to take a few
minutes to read this brief manual and familiarize yourself with the important information regarding product
features, setup and operation.

As with most electronic devices, we strongly recommend you to retain the original packaging. In the unlikely
event the product must be returned for servicing, the original packaging (or reasonable equivalent) is required.

S3125A

S3125A

Содержание PCT-610

Страница 1: ...Operation Manual Public Address Amplifier PCT 610 620...

Страница 2: ...by qualified service personnel only To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so Location...

Страница 3: ...tructions 2 Features 3 Operation 4 Additional Descriptions 4 Front Panel 5 Rear Panel 8 Connecting Speakers 11 FM Operation 12 CD Operation 13 Channel EQ SETUP 14 SETUP Mode 15 Applications 18 Block D...

Страница 4: ...alked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with th...

Страница 5: ...be used with the RS 232C terminal DIGITAL 3 BAND EQ Digital 3 band EQ for 6 Mic inputs PRIORITY MUTING Selectable audio signal priority for MIC Channel 1 and 2 Priority EM TEL IN RM MIC1 2 ANNOUNCEMEN...

Страница 6: ...if it is compressed to MP3 then it s capacity becomes about 4 5MB WMA WINDOWS MEDIA AUDIO WMA is a multimedia compression method developed by Microsoft Corporation and is the technology to compress o...

Страница 7: ...ection circuitry is activated If you want to release the protection directly then press the power switch 2 SPEAKER SELECTOR These switches are used to select output speakers The All button selects all...

Страница 8: ...1 Play Pause PRESET SCAN Button In CD function Play or Pause Button In FM function Preset Scan Button 2 PRESET PRESET Button In CD function Backward Skip and Forward Skip Button In FM function Preset...

Страница 9: ...etup mode Please refer to the CHANNEL EQ SETUP section page 14 and SETUP Mode section page 15 for details 16 MIC CHANNEL TONE CONTROL VOLUME Adjust the level of the 3 Band MIC Tone To adjust the level...

Страница 10: ...DC 24V When the DC 24V is discharged below 19 2V then the unit is entered in to the STAND BY mode 3 SPEAKER OUTPUT TERMINALS These terminals are for speaker wire connections Connect speakers which tot...

Страница 11: ...ME1 2 tone chime is activated 8 EXT MUTE Use these terminals to mute the signal of the unit externally Only EM RM or Tel In has priority over the EXT Mute 9 TEL IN TERMINALS These terminals can be con...

Страница 12: ...his input can be used to connect a tape player or other sound sources Input Level 30dBV 6dBV 15 PRE POST OUT PRE OUT This is the unbalanced output This output can be used to record the signal from the...

Страница 13: ...ING Extreme care must be exercised when connecting high impedance systems as potentially hazardous voltages may be present at these terminals Do not install this equipment in a confined space with les...

Страница 14: ...UNED you can hear the station MEMORY RECALL THE STATION 1 Choose the station you want with the TUNING TUNING button 2 Press the MEMO button and then the VFD lights MEMORY for about 10 seconds 3 Choose...

Страница 15: ...CT 1 Press the EJECT button to take out the disk 2 It eject the disk regardless of the current state REPEAT FUNCTION REPEAT 1 1 Repeats the single track 2 Press the REPEAT button during playing or pre...

Страница 16: ...nnel 5 Press the ENTER button to exit the EQ modes Auto save and Exit the EQ Mode when any key is not pressed for 10 seconds Please refer to the below example EX CH1 EQ SETUP HIGH 2dB MID 10dB LOW 0dB...

Страница 17: ...e same time to enter into the SETUP mode Turn the volume to enter into each setup function MIC 1 2 Mute level Tel In volume Chime volume etc Press the H button of the CH6 to exit the current setup fun...

Страница 18: ...p does not sound 5 IR REMOCON You can set the IR Remocon function on or off Turn the volume to choose IR REMOCON Press ENTER Choose ON or OFF Press ENTER ON Enable the IR Remocon function OFF Disable...

Страница 19: ...rd DRP 1 Choose 2 REC in DRP setup Press ENTER 2 Select the source of record CH1 or AUX IN Press ENTER 3 Press ENTER to start recording when DRP REC READY is displayed on the VFD 4 Count down 60 secon...

Страница 20: ...TEM PROG REV REPEAT TIMER DISC INTRO HIGH DENSITY 1 BIT D A CONVERTER RANDOM DIGITAL AUDIO COMPACT 1 2 3 4 5 1 2 3 4 5 6 7 8 9 10 11 12 13 14 PROG TRACK INDEX INTRO RANDOM REPEAT ALL 1 DISCS PRE AMPLI...

Страница 21: ...PUBLIC ADDRESS AMPLIFIER 19 PCT 610 620 Block Diagrams Block Diagrams...

Страница 22: ...Input Sensitivity 2 2dBV 10k S N A WTD 65dB Frequency Response 3dB 330Hz 3kHz CD Test CD 0dB 1kHz PRE OUT S N A WTD 85dB Frequency Response 3dB 80Hz 18kHz TUNER FM 22 5kHz MOD PRE OUT S N A WTD 60dB F...

Страница 23: ...ailable by contacting your warranty provider Variations and Options Variations and Options Variations Products supplied through legitimate sources are compatible with local AC power requirements Optio...

Страница 24: ...an company but rather a global company that is truly international in scope with factories and offices in Korea and China and sales and marketing operations located in Japan Europe and the U S A With...