16

PD-6359A

NOTE

Содержание 5A0C828364DB-1

Страница 1: ...Operation Manual Power Distributor PD 6359A Rack mount products in the Western Hemisphere North America South America and the Caribbean do not have handles installed due to customer preference...

Страница 2: ...ing instructions are for use by qualified service personnel only To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you ar...

Страница 3: ...fety Instructions 2 Features 3 Caution when assembling the Racks 3 Package and accessory includes 3 Equipment Setting and Checking 4 Front Panel 6 Rear Panel 7 Applications 10 Block Diagram 11 Specifi...

Страница 4: ...er apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding...

Страница 5: ...Block 5 08mm pitch 3P x 1EA 3 User manual x 1EA Features RACK SYSTEM POWER CONTROL It controls the power of the rack system AC OUTLET TERMINAL It being consisted of UNSWITCHED 1 group and SWITCHED 3...

Страница 6: ...t number Ex when number 1 and 3 switch is ON 1 and 4 is added so equipment number will be 5 2 TERMINATION Switch LOAD OPEN Setting 1 For the system linked by using RS 485 communication interface it is...

Страница 7: ...devices connected to this device 2 Remove the AC power cord then check the operation status with battery power in case of black out To prepare the black out the battery and battery charger PB 6207 is...

Страница 8: ...D 6359A s is switched to DC power battery from AC power due to a power failure then LED is turned on 5 SWITCHED LED After AC power or DC power is applied to the equipment then LED is turned on upon po...

Страница 9: ...SWITCHED 2 SWITCHED 1 Ex If BY PASS setting switch is all OFF position then AC power is output from SWITCHED 3 and then after 2 sec AC power is output from SWITCHED 2 At 2 sec later after AC power ou...

Страница 10: ...for stable data receiving transmitting of link in out For the details of Equipment Setting please refer to page 4 Caution communication error may occur if it is not set correctly 7 DC POWER OUTPUT TER...

Страница 11: ...It may cause electric shock Power overloading may cause the power to be turned off automatically to protect the circuit of the equipment Remove the cable connected to the DC power output terminal UNSW...

Страница 12: ...W N L H C REMOTE IN UNSWITCHED DC OUT 24V 1 2 4 8 1 2 3 4 16 ON ADDRESS BY PASS EMERGENCY OFF LINK TERM LOAD OPEN IN OUT MAX5A MAX5A MAX5A TOTAL MAX 5A SWITCHED 1 MAX10A 220 240V 50 60Hz 2400W SWITCHE...

Страница 13: ...CHED AC OUTLET GROUP1 AC OUTLET GROUP2 AC OUTLET GROUP3 DC TERMINAL RACK ONLY DC TERMINAL EMERGENCY DC TERMINAL UNSWITCHED DC TERMINAL AMP ONLY HARDWARE MCU CONTROL DC SOURCE AC SOURCE CONTROL Display...

Страница 14: ...A Max RACK ONLY 4 channel 24V 5A Max Sequential Power Delay BY PASS 2 sec 0 5 step Communication RS 485 Operation Temperature 10 C 40 C Power Source AC 220 240V 50 60Hz Power Consumption 5 8kW Weight...

Страница 15: ...POWER DISTRIBUTOR 13 PD 6359A DIMENSIONS 440 280 482 132...

Страница 16: ...le by contacting your warranty provider Variations and Options Variations and Options Variations Products supplied through legitimate sources are compatible with local AC power requirements Options No...