2
DISPLAY
BUTTONS
MANUAL OPERATION
ACTIVITY TIMER
GEN SET ACCESS
The
can display the time of day, battery voltage, generator run time, and the air conditioner
thermostat position.
To scroll through the different displays, press either the “UP” or “DOWN” buttons.
The
corresponding LED indicator will illuminate to let you know which mode you are viewing.
Generator Logic Control
-
To manually start or stop the generator, press and release the START/STOP button. When starting, the
generator will crank the starter for 5 seconds. If the generator does not start, it will attempt again. If the
generator does not start after the fifth attempt, the display will read “GEN FAIL”.
When the generator is started, a timer is started in the controller. The timer counts down from 24 hours. If at the
end of 24 hours, no activity has been observed on the coach, the controller will exit from auto mode and the
generator will stop. If activity has occurred, the controller will stay in auto mode. This is a safety feature in the
event that the auto mode has been left on unintentionally. Many manufacturers use a switch at the entrance
door, which will operate as the door is opened and closed to tell the controller that there is activity. The time
remaining on the activity timer can be observed by pressing the up down buttons until “TMR” is illuminated.
If the generator access door is open, the auto start feature is disabled and the display will flash “
”.
TIME
STOP TIME
.
START TIME
START/STOP
button displays the current set time.
button displays the time of day the generator will automatically shut off if pressed. Pressing it
once activates the auto shutoff
Pressing it a second time turns the auto shutoff off. When auto shutoff is
active, the button will be illuminated.
button displays the time the GLC will go into “AUTO” mode. Pressing the button once turns it
ON and another press turns it OFF. When active, the button will be illuminated.
button starts or stops the generator with a single push
depending on the state of the generator. If
, the button will turn the generator
f
, the button will
turn the generator
. When the generator is
, the light just above the button will illuminate.
button puts the GLC into auto start mode. When in this mode the generator will start if the air
conditioner calls for cooling or the battery voltage gets too low. The button will illuminate whenever in auto
start mode. To turn OFF auto start mode, press the button until light is no longer ON.
OFF
ON. I ON
OFF
ON
AUTO
(do not hold the button down)
DOOR
DIP SWITCH SETTINGS
Set dip switch 1 and 2 for (S11) as follows:
1
ON
Diesel
3
Not Used
OFF Gas
4
Not Used
2
ON
Pulse Crank
OFF
5 second Crank
SPST
DIP
4
S
WITCH
SPST
DIP
4
SWITCH
ON
OFF
1
2
3
4
OPERATING GUIDE
131 Eisenhower Lane North
Lombard, IL 60148
630.268.0010 / 1.800.251.2408
Generator Logic Control
P/N 53-00859-100 Rev. B 050405
www.intellitec.com
Intellitec