The Generator Logic Control (GLC) is designed to automatically start or stop a generator. Depending upon how the
control is set, the Generator will start when either the battery voltage becomes too low, the air conditioner calls for
cooling, or the time of day for auto-start has occurred. In addition to starting the generator, the control can be set to
stop the generator at a specific time.
If the control is set for
, the generator will start when the house batteries are low (below 12.1 Volts) and will run
until the battery voltage has exceeded 13.3 volts for one hour. The generator will also start if the thermostat calls for
air-conditioning.
When the generator has been started for air conditioning, the generator will run until the
thermostat's setting is reached, plus an additional 10 minutes.
To enter Auto mode, press the button marked “AUTO”, the indicator light on the button will light. When the generator
is running, the lightning bolt symbol will illuminate. To turn auto mode off, press the Auto mode button.
Regardless of the mode, the generator can be started or stopped by pressing the start/stop button. Following the
directions below, a start time and stop time can be entered in to the controller. When the start time is reached, the
control will go to the auto mode. The generator will start if the battery voltage is low or the thermostat is requesting air
conditioning. The generator will function per the description in AUTO above. When the stop time is reached, the
generator will stop and auto mode will be cancelled. Start and or Stop time is enabled when the push button indicator
light is illuminated. To cancel either the start or stop time, press the button.
To set the time of day, stop time or start time, press and hold the corresponding button for three seconds until the hour
digit flashes. Push the “UP” or “DOWN” button to set the hour. Press the desired button again and the minutes will
flash. Press the “UP” or “DOWN” buttons to set the minutes. When finished, press the desired button once again to
lock in the time.
When starting the generator, the Generator Logic Control will crank the generator for 5 seconds. If it has not started
by the end of that time, it will stop for 5 seconds and retry again. If, after the fifth attempt the generator does not start,
“GEN FAIL” will flash on the display. To clear this message, press the “START/STOP” button.
AUTO
START/STOP, START TIME, STOP TIME
SETTING TIME
“AUTO”
OPERATING GUIDE
131 Eisenhower Lane North
Lombard, IL 60148
630.268.0010 / 1.800.251.2408
Generator Logic Control
P/N 53-00859-100 Rev. B 050405