9
53-22130A100
131 EISENHOWER LANE NORTH
LOMBARD, ILLINOIS 60148-5413
630-268-0010 / 1-800-251-2408
ELECTRONIC CLIMATE CONTROL
INTELLITEC
USE WITH 5 KW GENERATOR
In systems using 5 KW generator sets, an additional change-over or transfer relay is used to transfer the load
of the larger A/C system (usually the front system) to the generator’s second output to utilize generator's full
output capability. In this situation the ECC load shedding features will remain unchanged, but the Current
Sensor will not measure the load current going to the larger (front) A/C system when the generator is running.
If the measured load currents through the current sensor continue to exceed 30 Amps with the smaller (rear)
A/C system shed, the ECC Control Module will shed the larger (front) A/C system to prevent over load of the
generator.