6
2.2 Connector definition
The control wire is from bottom of PT system.
Definition as follows:
No.
Description
Remark
1
RS485
RS485+
2
RS485-
4
CCD Video
Analog video output of CCD camera
5
IR Video
Analog video output of thermal imaging camera
6
AC24V
Power supply
7
3
OPERATION GUIDE
3.1 Communication parameters
Thermal camera default address
:
PELCO-D
、
baud
9600
、
address
2
PT system default address
:
PELCO-D
、
baud
9600
、
address
1
Visual camera default address
:
PELCO-D
、
baud
9600
、
address
1
Protocol board address
:
PELCO-D
、
baud
9600
、
address
1