950P
Portable Air Cleaning System
950P
Portable Air Cleaning System
#10065
10
© Intellipure 2015
#10065
11
© Intellipure 2015
Receiving and Unpacking
System Overview
UNPACKING AND INSPECTION
To prevent damage during shipping, the V-
Bank Main Filter and High Energy Grid
Assembly are packaged separately from
the main unit.
To un-crate, remove the strapping, box tops
and additional wrappings around the unit
and V-Bank Main Filter and High Energy
Grid Assembly.
Inspect for damages not previously evident.
Lock the (2) front wheels to secure the
unit.
(fig-A)
Remove the Filter Access Door located in
the back of the unit using the four butterfly
latches located on the sides of the unit.
Lift the latch wings (4) and turn
counter-clockwise to open.
(fig-B)
Filter Access Door removal may require a
firm pulling effort.
Slide the V-Bank Main Filter and High
Energy Grid Assembly into the unit. Take
note that the labels will be facing outward
with the airflow arrow pointing upwards.
(fig-C) (fig-D)
Using the Magnetic Bit Holder provided,
alternate tightening the left and right
Scissor Locking Mechanisms located near
the motor plate in the filter.
(fig-E)
Connect the High Voltage Lead.
(fig-F)
Ensure the Prefilter is firmly seated.
The unit will not run if the Prefilter is
not installed correctly.
(fig-G)
Return the Filter Access Door. Lift the
latch wings (4) and turn clockwise
to close.
(fig-H)
UNIT DESCRIPTION
The 950PAir Cleaning System is a high performance system that utilizes patented award winning
Disinfecting Filtration System technology. DFS technology electrically enhances a low efficiency, high flow,
low-pressure drop filter to high efficiency while retaining the low pressure drop and longer life advantages of
the base filter material. This technology has also been shown to inhibit bacteria growth on the filter.
The 950PPortable DFS Air Cleaning System is available in the following models:
Model
Power Requirement
Air Flow Capacity
V
Hz
Phase
Low
Medium
High
Turbo
950P
120
50/60
1
334 m
3
/hr
660 m
3
/hr
1000 m
3
/hr
1500 m
3
/hr
210 CFM
415 CFM
630 CFM
950 CFM
950P
220
50/60
1
334 m
3
/hr
660 m
3
/hr
1000 m
3
/hr
1500 m
3
/hr
210 CFM
415 CFM
630 CFM
950 CFM
Height
Width
Depth
Weight
Ship Wt
950PUnit
44in
1,118mm
18in
457mm
28in
711mm
155 lb
70 kg
254 lb
116 kg
V-Bank VOC Filter
57in
1,448mm
18in
457mm
28in
711mm
81 lb
37 kg
fig-B
fig-D
fig-F
fig-A
fig-C
fig-E
Do not over-tighten the
Scissor Lock Clamps.
fig-G
fig-H
Please confirm your model number and follow the instructions for that model. The
electrical power requirements for each individual unit are on the data plate label
adjacent to the electrical connections. These requirements supersede all other
inferences to power requirements.