Controls
1. Attack CV Input Attenuator
-
Controls the range of CV
modulation applied to the
function’s attack phase. The
range increases as the knob turns
clockwise. Generally best results
are achieved by starting at zero
and then increasing the amount
until the desired level of
modulation is discovered.
2. Decay CV Input Attenuator
-
Controls the range of CV
modulation applied to the
function’s decay phase.
3. End of Cycle LED
- Indicates the
completion of an envelope’s
decay phase, corresponding with
a gate signal sent out of the
EOC
output.
4. Quad 1+2 Mode Switch
-
Engages
Quadrature Mode
for
1+2
. When on (switched to the
right), function
1
’s end of attack
will trigger function generator
2
.
5. Quad 3+4 Mode Switch
-
Engages
Quadrature Mode
for
3+4
. When on, function
3
’s end of
attack will trigger function
generator
4
.