background image

Pag.8   

 www.intelligenthanddryers.com

Dryflow® Vapordri Hand Dryer

4. OPERATION

4.1 Drying

To switch the hand dryer on it must be connected to the power supply and the internal illuminated 

switch must be ON.

NOTICE: When the device is delivered the internal switch is ON, so it is not necessary to remove the 

front cover to activate it.

When hand dryer is switched on, it automatically carries out an internal check; after some seconds it 

will be ready to use.
The right way to use the hand dryer is by introducing vertically both hands, separated, so that they 

can be correctly detected by IR sensors. 

When  motor  starts,  countdown  will  be  shown  on  the  display  of  the  device,  which  is  similar  to  a 

barcode. The optimal drying time would be one cycle of the barcode display. However if the user 

wishes to continue with the drying, another cycle will start automatically without being necessary to 

remove hands and introduce them again. Maximum drying time is 30 seconds.

Hand dryer automatically switches off when removing hands.

1 2 3 4

If blinking means

problems with IR and / or end of cycle

30 seconds

Alarms

Duraon of drying cycle

Содержание Dryflow Vapordri

Страница 1: ...Dryflow Vapordri Hand Dryer INSTALLATION MANUAL ...

Страница 2: ...ly careful when removing the cover of the hand dryer as some active parts of the device will be exposed involving risk of electric shock Turn off all power sources before carrying out any electric handling in order to avoid risk of electric shock The device must be installed out of reach of any water point respecting safety distances established by the current IEC Regulations INDEX 1 SAFETY INSTRU...

Страница 3: ... has RCD of high sensitivity 0 03A The device can be used by children over 8 as well as by people with reduced capacities either physical sensorial or mental and by people with lack of experience or knowledge if they are supervised or if they receive some training about how to use the device in a safe way and which are the risks involved Childrenmustnotplaywiththedevice maintenance cannot be carri...

Страница 4: ... is easy to access clean and remove Antibacterial ABS The device is manufactured from ABS plastic which contains some additives that avoid proliferation of bacteria fungi and mould Water tank Hand dryer has a wáter tank to recover wáter from hands during drying process The wáter tank must be empty and cleaned regularly High performance and low consumption Heating element of the device turns off au...

Страница 5: ...s power cord through and screw it to connection strip Screw duct provided as a protection to prevent cord to be pulled accidentally NOTICE Power cord is not supplied with the device it must be installed by a qualified technician Cable MUST BE TYPE H05RN F 2 x Ø 1 5mm Connec on strip for power cord to network 230V 50Hz Restraint system for power cord an pull protec on POWER CORD H05RN F 2 x Ø 1 5mm...

Страница 6: ...ill be necessary to calibrate sensors again This can be done by removing front cover To disassemble front cover remove two screws at the bottom and slide it vertically upwards where you will find main switch of the device The switch will be set in ON position when the device is delivered Screws for wall fixing It is recommended to use screws and wall plugs in all 5 fixing holes Z shows required di...

Страница 7: ...ctronical components Turn potentiometers with a flat head screwdriver clockwise or counterclockwise whichever applies IR SENSORS REGULATION Electronical plate with poten ometers to calibrate hand detec on sensors Right Sensor Le Sensor P1 Right sensor sensitivity turn clockwise sensitivity turn counterclockwise P2 Left sensor sensitivity turn counterclockwise sensitivity turn clockwise ...

Страница 8: ...ight way to use the hand dryer is by introducing vertically both hands separated so that they can be correctly detected by IR sensors When motor starts countdown will be shown on the display of the device which is similar to a barcode The optimal drying time would be one cycle of the barcode display However if the user wishes to continue with the drying another cycle will start automatically witho...

Страница 9: ... released from the hands during drying The water will be taken to a small water tank located at the bottom of the hand dryer The water tank is accessible from the bottom of the hand dryer It has a latch for release and removal for emptying and cleaning 4 3 1 Flooding due to misuse or breakdown of the device For safety reasons if flooding occurs due to misuse of breakdown wáter tank has been design...

Страница 10: ... and then filter can be removed easily Motor brushes 3 Notification of wear of motor brushes they need to be replaced After replacement of brushes please reset the motor counter following instructions included further in this section Intelligent Facility Solutions logo blinking It means that 30 seconds programmed drying cycle is finished If sensors detect a static object for longer than 30 seconds...

Страница 11: ...hours counter and therefore it shows when the brushes have been changed To resetcounter pressthebutton and at thesametime turn on thedevicebymeansof theilluminated pushbutton Please keep it pressed until the first bar illuminates Once the pushbutton is released the counter is reset to zero and all the bars light up continuously Button to reset motor counter ...

Страница 12: ...mpty water and clean water tank Insert cover again and insert water tank in hand dryer again When triangle symbol shines water tank is almost full Please empty water tank following below instructions The tank is located at the bottom of the hand dryer 1 2 3 4 5 6 Release tank by turning lock Attach water tank by turning lock ...

Страница 13: ...ONEXION DIAGRAM Circuits PW Power circuit CN Control circuit LED Leds air nozzles IR IR sensors circuits DS Display PT Pressure temperature sensor Pushbuttom Boton reset for motor counter Main switch AC Input Terminal block Blower Motor Motor 1 kW 230 V 50 Hz Air heater ...

Страница 14: ...tion system to indicate protection levels provided by an enclosure to preventaccesstodangerousparts penetrationofforeignbodies penetration of water and to add further information to protection reference V Voltage AC Alternating current Hz Frecuency in Hertz W Power in Wats Electrical insulation CLASS II Grounding wire not required CE European Community Marking RoHS WEEE European Directive on waste...

Страница 15: ...mercury cadmium hexavalent chromium prolybrominated biphenyl PBB or Polybrominated diphenyl ethers PBDE or Phthalates This symbol of a crossed out wheelie bin can be found on the characteristics sheet of the hand dryer It means that at the end of the life of the device it must not be disposed of with the household waste To facilitate recycling and avoid negative consequences for the environment an...

Страница 16: ...ELLIGENT FACILITY SOLUTIONS LTD Electric House 51 Wisewood Road Sheffield S6 4TB United Kingdom Phone UK 44 0 114 354 0047 Phone Eire 353 190 36387 sales ihdryers co uk https www intelligenthanddryers com ...

Отзывы: