POWERING / CHARGING DEVICES WITH M1000

Select the type of outlet required by pressing the Output ON/OFF Button

. The

output port will NOT function until the appropriate button is pressed to activate the port.
When activated, the indicator on the button will illuminate blue, indicating that the
output(s) are active, and the LCD display will turn on and provide details on the
charging output. The LCD Screen will automatically shut down when no outputs are
activated.

intelligentenergy M1000 will enter sleep mode after 180 seconds of inactivity (no new
output load detected), and will "wake up" when inputting a charging cord or when any
button is pressed. Press the ON/OFF button(s) to shut down the output(s) when not in
use.

PASS-THROUGH CHARGING

The advanced battery management system of the intelligentenergy M1000 allows it to
charge a connected device via DC output & USB output while charge the intelligentenergy
M1000.

DO NOT

CONNECTED DEVICE VIA AC OUTPUT WHILE CHARGE THE

intelligentenergy M1000.

OVERLOAD CONDITION

If an overload condition occurs on the OUTPUT port, intelligentenergy M1000 will:

Automatically turn off AC Output power.
The indicator

of LCD Screen will be illuminated.

Do following:

Check the input charge cable. The port will be efficient when the input charge cable meets

the specification outlined in the GENERAL SPECIFICATIONS section.

Only charge intelligentenergy M1000 with provided AC wall power adapter.

M1000 ACCESSORY LIST

18V-23V with Mc4

110V or 230V AC wall plug

12V-14V Car Charger

User Manual

connector cable

power adapter

cable

Recommend to use 150W Solar panel (not included).

9

Содержание M1000

Страница 1: ...制作要求 此页不印刷 成品尺寸 142x210mm 展开尺寸 284x210mm 钉装 骑马钉材质 铜版 纸 ...

Страница 2: ...INTELLIGENTENERGY M1000 USER MANUAL RECOMMENDED TO FULLY CHARGE M1000 BEFORE USE ...

Страница 3: ...0W Rated capacity 999Wh Standard capacity 3 7V 270000mAh Overload protection Power 1100 80W Output waveform pure sine wave USB output QC3 0 18W 3 Output Type C PD60W 1 Cigarette Lighter Socket Output 12V 14V 10A DC 55 2 1 output 12V 14V 5A 2 Wireless charger 5W 7 5W 10W Charging input voltage 12V 26V Working temperature 10 40 C Weight net weight 8 9kg Weight including accessories 9 5kg Product siz...

Страница 4: ...ng with M1000 unless they have been given supervision or instruction concerning use of it by a person responsible for their safety DO NOT attempt to repair M1000 or AC Wall plug power adapter There are no user serviceable components inside DO NOT handle M1000 with wet hands DO NOT place M1000 on its side or upside down while in use or in storage If rust odor overheating or other abnormal circumsta...

Страница 5: ... 8 Wireless Charger 9 Handle 10 straps hooks 11 Air Intake Vent with Cooling Fan 12 Solar Charging Input 13 DC input Note No user serviceable parts inside Recommended to fully charge the M1000 before use 1 Power ON OFF Button 2 USB Output Power ON OFF Button 3 SOS mode LED light Button 4 AC Output Power ON OFF Button 5 SOS mode LED light Button 6 DC Output Power ON OFF Button 3 ...

Страница 6: ...12V 10A 7 9 hours when car running From Wall Charger 110V or 230V 6 7 hours DO NOT CONNECT DEVICE VIA AC OUTPUT PORT WHILE CHARGING THE M1000 RECOMMEND TO DISCONNECT THE M1000 WHEN FULLY CHARGED WHAT IT POWERS Laptops 41 4Wh 32 TV 60W CPAP without heated Gopro 5 9Wh Floodlight 4W Around Around humidifier 15W Around Around 20 Recharges 14 hours 53hours 135 Recharges 200 hours MORE Mini Fridge 40W D...

Страница 7: ...sh one more time again will turn off the light If both LED lights have been actived press button or just button can control both LED light at the same time If you want to power both LED off needs to press both buttons and DC OUTPUT POWER ON OFF The DC output port will NOT function until the appropriate Button are both pressed to activate Press Button to shut down the output s When not in use USB O...

Страница 8: ... Press ON OFF Button before charging Press ON OFF Button to shut down the output s When not in use COOLING FAN 12 intelligentenergy M1000 utilizes an internal cooling fan to ensure the product is operating within the appropriate temperature range intelligentenergy M1000 when it experiences a higher output load will automatically turn on the fan During discharge and possibly charging the fan may op...

Страница 9: ...es as the energy draw changes from the connected devices This is evident during initial activation of ports with a connected device RECOMMENDED back to charge the intelligentenergy M1000 when battery indicate less than 20 Note that when you first plug in a power source whether it s a solar panel or a wall charger the intelligentenergy M1000 may take a minute to detect and adjust its charge circuit...

Страница 10: ...1000 to fully charge prior to use approx 6 8 hours When charging the LCD Screen will be illuminated and the LCD display will provide Battery level Indicator A intelligentenergy M1000 is fully charged when the level is 100 It is recommended to fully charge intelligentenergy M1000 every 3 months to maintain the health of the battery pack 8 ...

Страница 11: ...hen not in use PASS THROUGH CHARGING The advanced battery management system of the intelligentenergy M1000 allows it to charge a connected device via DC output USB output while charge the intelligentenergy M1000 DO NOT CONNECTED DEVICE VIA AC OUTPUT WHILE CHARGE THE intelligentenergy M1000 OVERLOAD CONDITION If an overload condition occurs on the OUTPUT port intelligentenergy M1000 will Automatica...

Страница 12: ...below specific storage range can also harm intelligentenergy M1000 performance and service life Keep away from corrosion chemicals and gases After taking out of storage visually inspect to make sure intelligentenergy M1000 and all accessories look satisfactory This increase review the intake and exhaust side vents to ensure they are clear of debris Allow intelligentenergy M1000 to return to ambien...

Страница 13: ... wait 1 2hours to recharge again after AC discharging from 100 to 0 uninterruptedly Avoid discharging completed on a regular basis as this can impact overall life Regularly inspect all ports and wall charger for any debris dirt damage and corrosion DO NOT attempt to fix DO NOT cover the intelligentenergy M1000 with towels clothing or other items Regularly observe if the side vents are collecting d...

Страница 14: ...lligentenergy s option any intelligentenergy product that fails to operate during the applicable warranty period due to defect in workmanship or material If a valid claim is made during the applicable period intelligentenergy at its option will either 1 replace the product or 2 exchange the product with a product that is of equal value A replacement product assumes the remaining warranty of the or...

Страница 15: ...To reduce risk of battery explosion follow these instructions and those published by battery manufacturer and manufacturer of any equipment you intend to use in vicinity of the battery Review cautionary marking on these products and on engine When charging the internal battery work in a well ventilated area and do not restrict ventilation in any way m Under abusive conditions liquid may be ejected...

Страница 16: ...by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help To maintain compliance with FCC s RF Exposure guidelines This equipment should be inst...

Отзывы: