9
3 Assembly
3.1 Connecting output power cables
The output power leads can be connected to the FCPM once the PCM has
been disconnected.
Note All the power leads require an M8 ring terminal to attach to the POM.
1. Ensure battery is isolated from the cables before connecting to the POM,
use a suitable connector between battery and ring terminals for the power
rating of the application.
2. Complete the steps to open the FCPM section 3.1.1.
3. Feed the cable through the housing, connect battery positive M8 Ring
to ‘Batt +’ and battery negative to common ground ‘GND’.
4. Connect load positive to ‘PWR +’ and load negative to common ground ‘GND’.
5. Use the bottom terminal with an M8 button head screw to attach the cable
(max. torque 1.5Nm).
6. Feed the cable through the housing, battery positive (connector 3).
7. Use the top terminal with an M8 button head screw to attach the cable
(max. torque 1.5Nm).
8. Feed both the battery negative cable and the output negative cable through
the housing, ground (connector 1).
9. Use the middle terminal with an M8 button head screw to attach the cable
(max. torque 1.5Nm).
10. Once the cables are in place reconnect the SPM as in section 3.1.2.
Note The negative stud is common to the battery and output