User Manual | CMR-6100
11 Intelleflex Confidential
3.4
Upgrading Reader Firmware
Upgrading the Firmware on the CMR-6100 is done through the “Firmware Upgrade” tab under “Admin”.
Obtain the latest version of the FW through the Intelleflex website or contact the Intelleflex Support
department if you believe that your firmware version is out of date or if you are experiencing any
problems using the web based interface.
Figure 3.4-1 Reader Firmware Upgrade Page
3.5
Basic Inventory Demo
The Demo’s tag Inventory page is the main page used to interface with tags. From this page the user
has the ability to inventory tags with different RF and reader parameters, read and write to tag user
memory, and verify functionality of the system.
Figure 3.5-1 Inventory and Search Configuration Page
Reader parameters are controlled via “config” lines. A single config line or multiple config lines may be
used. A config line is a command sent to the reader telling it what parameters and settings to use during
an inventory action. Within each config line, the following reader parameters can be set:
•
Protocol – C3 or C1G2
•
Power level in dBm, between 0 and +30 dBm
•
Q value, between 0 and 13
•
Tx and Rx antenna
•
Performance Profile
Protocol:
Select C3 or C1G2 operation from the Protocol dropdown menu. Two config lines can be used
to have the reader read a mixed tag population simultaneously.
Power:
Set between 0 and full power of +30 dBm. Use full power to read C3 tags at long range.