1.
Verify a remote Intelix twisted pair receiver is connected to the DIGI-
VGASD-8X8e matrix via twisted pair cable.
2.
Connect an Intelix DIGI-VGASD-IREYE IR receiver (sold separately) to
the twisted pair receiver.
3.
Connect an Intelix DIGI-VGASD-IREMT IR emitter (sold separately)
directly to the DIGI-VGASD-8X8e. The emitter’s 1/8” mini (3.5mm) plug
connects to the matrix. Each audio/video source requires an independent IR
emitter.
4.
Affix the IR emitter to the audio/video source.
IR Emitter Mounting Tips
Surrounding electrical equipment may be producing high levels of
IR noise. Plasma TVs and compact fluorescent lights are known
polluters. Shield the outside of the emitter and the hardware’s IR
window with electrical tape.
Verify the emitter is directly on the hardware’s IR window and
directly over the IR sensor. Operation may be intermittent if the
emitter is too far away from the sensor.
Clean the equipment’s IR sensor window with an alcohol-based
cleaner before applying the emitter to guarantee adhesion.
Should the emitter not adhere to the equipment’s sensor window,
apply a small drop of glue to the adhesion pad on the emitter and
re-apply.
Warning!
Do
not
use any IR receiver or IR emitter other than those
sold exclusively for the DIGI-VGASD series of products to prevent
damage to the unit. Using 12V-based IR components may permanently
damage the IR circuitry of the product and void the warranty.