Intel
®
Server System SR1520ML User’s Guide
75
System Environmental Specifications
Table 6. System Environmental Specifications
Temperature
Non-operating
Operating
-40 ° to 70 °C.
10 ° to 30 °C, with the maximum rate of change not to exceed 10 ° C per
hour.
Humidity
Non-operating
90% relative humidity, non-condensing at 35 °C.
Shock
Operating
Packaged
2.0 g, 11 msec, 1/2 sine.
Operational after an 24-inch free fall.
Acoustic noise
7 Bels in sound power for a typical office ambient temperature (65-75 °F).
Your selection of peripherals may change the noise level.
Electrostatic
discharge (ESD)
Tested to 15 kilovolts (kV); no component damage.