54
Intel
®
Server System SR1520ML User’s Guide
The lithium battery on the server board powers the RTC in the absence of power. When
the battery starts to weaken, it loses voltage, and the server settings stored in CMOS RAM
in the RTC (for example, the date and time) may be wrong. Contact your customer service
representative or dealer for a list of approved devices.
Warning: Danger of explosion if battery is incorrectly replaced. Replace only with the same or
equivalent type recommended by the equipment manufacturer. Discard used batteries
according to manufacturer's instructions.
Advarsel:
Lithiumbatteri - Eksplosionsfare ved fejlagtig håndtering. Udskiftning må kun ske med
batteri af samme fabrikat og type. Levér det brugte batteri tilbage til leverandøren.
Advarsel:
Lithiumbatteri - Eksplosjonsfare. Ved utskifting benyttes kun batteri som anbefalt av
apparatfabrikanten. Brukt batteri returneres apparatleverandøren.
Varning:
Explosionsfara vid felaktigt batteribyte. Använd samma batterityp eller en ekvivalent typ
som rekommenderas av apparattillverkaren. Kassera använt batteri enligt fabrikantens
instruktion.
Varoitus:
Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan
laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden
mukaisesti.
1. Observe the safety and ESD precautions at the beginning of this book. See
“Safety
Information” on page iii
.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the server system cover. For instructions, see
“Removing the Server
System Cover” on page 14
.
4. Remove the server's cover and locate the battery. See
Figure 43
.
5. Pull back gently on the metal tab at the top of the battery.
6. Remove the battery from its socket.
Содержание SR1520ML - Server System - 0 MB RAM
Страница 6: ...vi Intel Server System SR1520ML User s Guide...
Страница 12: ...xii Intel Server System SR1520ML User s Guide...
Страница 14: ...xiv Intel Server System SR1520ML User s Guide...
Страница 62: ...42 Intel Server System SR1520ML User s Guide Figure 34 Removing Bracket and Fans AF002507 B A...
Страница 78: ...58 Intel Server System SR1520ML User s Guide...
Страница 90: ...70 Intel Server System SR1520ML User s Guide...
Страница 96: ...76 Intel Server System SR1520ML User s Guide...
Страница 108: ...88 Intel Server System SR1520ML User s Guide...
Страница 118: ...98 Intel Server System SR1520ML User s Guide...
Страница 122: ...102 Intel Server System SR1520ML User s Guide...
Страница 126: ...106 Intel Server System SR1520ML User s Guide...
Страница 150: ...130 Intel Server System SR1520ML User s Guide...