![Intel SMALL BUSINESS SERVER Скачать руководство пользователя страница 75](http://html.mh-extra.com/html/intel/small-business-server/small-business-server_manual_2073408075.webp)
- 75 -
Troubleshooting
In addition to problems and solutions listed below, see
release notes.txt
file provided on
Small
Business Server Hardware Deployment CD
for a list of known issues and workarounds.
Problem
Suggested Solution
Booting the System
System will not POST
Check that processor and DIMMs are fully seated in
their sockets
Check that DIMMs are correctly populated.
Check that J9H3 jumper is set to pins 1-2 (Normal
Operation mode).
No video, though fans are spinning
If you are using KVM switch, connect keyboard, mouse, and
monitor directly to the system
Operating system will not boot.
Make sure that correct boot device is selected in the system
BIOS setup.
RAID Array
RAID Controller may report that
"Battery life is low" during POST.
This is likely a false warning if the
Battery Backup Unit is new.
In RAID BIOS Console go to Adapter Properties
Click on Present link next to Battery Backup
If Voltage is shown as Good, click Reset button
Number of cycles should reset to zero and the warning
during POST should disappear.
Drives are not detected
Make sure that the cable ends are connected properly.
Make sure that the power cables to the hot swap
backplane are connected properly.
Change cables.
If everything fails, change the drive(s).
An error occurs while reading the
configuration data on a drive.
The drive is bad and needs to be replaced.
BIOS reports that the RAID array is in
degraded mode.
Make sure all physical drives are properly connected and
are powered on.
Reconnect, replace, or rebuild any drive that has failed.
One of the hard drives in RAID-5 array
has failed.
Replace the failed drive with another drive that has the same
or greater capacity.
Содержание SMALL BUSINESS SERVER
Страница 17: ... 17 ...
Страница 46: ... 46 11 At the Instance Name screen select Default instance and click Next ...
Страница 68: ... 68 ...