Table 5.  Abbreviated List of POST Error Messages

POST

message

Failing device or problem found

Suggested action

161

The real-time clock battery has 
failed.

Replace the battery yourself or call for service.

162

A device configuration has 
changed.

Make sure that optional devices are installed correctly 
and turned on. 

NOTE:

If you are unable to start the Configuration/
Setup Utility program, view the system event 
log in the management module.

163

The time of day has not been set.

Set the date and time.

289

A failing DIMM was disabled.

Make sure that the installed memory is correct for your 
blade server type and that it is installed properly.

301

303

Keyboard and keyboard controller

Make sure that the keyboard/video/mouse select 
button LED on the front of the blade server is lit, 
indicating that the blade server is connected to 
the shared keyboard.

Make sure that the keyboard cable is connected 
to the Intel® Blade Server Chassis SBCE and 
nothing is resting on the keyboard keys.

962

Parallel port configuration error

Start the Configuration/Setup Utility program and 
make sure that the parallel-port setting is correct. 

11

xx

Serial port error 

Make sure that the serial cable is connected correctly.

1162

Serial port configuration conflict

Start the Configuration/Setup Utility program and 
make sure that the IRQ and I/O port assignments that 
are needed by the serial port are available. 

1800

PCI adapter hardware interrupt

Start the Configuration/Setup Utility program and 
make sure that the interrupt resource settings are 
correct.

2400

2462

Video controller and memory

Make sure that the keyboard/video/mouse select 
button LED on the front of the blade server is lit, 
indicating that the blade server is connected to 
the shared monitor.

Make sure that the monitor is connected correctly 
to the Intel® Blade Server Chassis SBCE.

00019

xxx

Processor

 x 

is not functioning or 

failed the built-in test.

Make sure that processor

 x 

is installed correctly. If the 

problem remains, replace processor

 x

.

00180

xxx

A PCI adapter requested a 
resource that is not available.

Start the Configuration/Setup Utility program and 
make sure that the resources that are needed by the 
PCI adapter are available. 

01295085

The blade server failed the ECC-
checking hardware test.

Have the system board serviced.

012980

xx

012981

xx

Data for processor 

x

Download and install the latest level of BIOS code.

01298200

Microprocessor speed mismatch

Install microprocessors with identical speeds.

Содержание SBXD62 - Server Compute Blade

Страница 1: ...Intel Server Compute Blade SBXD62 Installation and User s Guide A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies Products Intel Order Number D50275 002...

Страница 2: ...cifications and product descriptions at any time without notice Intel server boards contain a number of high density VLSI and power delivery components that need adequate airflow for cooling Intel s o...

Страница 3: ...ing the Control Panel and LEDs 8 System Board Illustration 10 Using System Board Switches 11 Using Light Path Diagnostics to Troubleshoot the System Board 12 Installing Options 15 Installation Guideli...

Страница 4: ...roubleshooting Charts 46 Memory Problems 46 Microprocessor problems 47 Monitor Problems 47 Mouse Problems 48 Network Connection Problems 49 Option Problems 49 Power Problems 50 Service Processor BMC P...

Страница 5: ...D 68 Other Hazards 69 Deutsch 70 Sicherheitshinweise f r den Server 70 Sicherheitshinweise und Vorsichtsma nahmen 70 Zielbenutzer der Anwendung 71 Standortauswahl 71 Handhabung von Ger ten 71 Warnhinw...

Страница 6: ...nd User s Guide D Getting Help 93 World Wide Web 93 Telephone 93 U S and Canada 93 Europe 93 In Asia Pacific region 94 Japan 94 Latin America 94 E Installation Assembly Safety Instructions 97 English...

Страница 7: ...ion and User s Guide vii List of Tables Table 1 Switch Block 2 SW2 Settings 11 Table 2 System Board LEDs 13 Table 3 Light Path Diagnostics Panel LEDs 13 Table 4 POST Beep Code Descriptions 44 Table 5...

Страница 8: ...viii Intel Server Compute Blade SBXD62 Installation and User s Guide...

Страница 9: ...cherheitshinweise zu Intel Serverplatinen und Servergeh usen unter http support intel com support motherboards server sb cs 010770 htm Consignes de s curit Lisez attention toutes les consignes de s cu...

Страница 10: ...mage can result Electrostatic discharge ESD and ESD protection ESD can damage disk drives boards and other parts We recommend that you perform all procedures in this document only at an ESD workstatio...

Страница 11: ...ating system Performing basic troubleshooting of the blade server Record information about your Intel Server Compute Blade SBXD62 in the following table Note The model number and serial number are on...

Страница 12: ...ontains information to help you solve problems yourself It also contains information for service technicians Notices and Statements Used in this Document The following notices and statements are used...

Страница 13: ...aximum Type 2 way interleaved DDR2 PC3200 ECC SDRAM registered x4 Intel x4 Single Device Data Correction DIMMs only Supports 256 MB 512 MB 1 GB 2 GB and 4 GB 4 DIMM slots Drives Support for two intern...

Страница 14: ...chnology I O expansion The blade server has connectors on the system board for an optional expansion card such as the Fibre Channel expansion card for adding more network communication capabilities to...

Страница 15: ...itoring for temperature voltage hard disk drives and flash drives x4 SDDC memory for DIMMs with a capacity of 512 MB or greater Customer upgradeable basic input output system BIOS code Customer suppor...

Страница 16: ...hassis SBCE and remove the cover to see the components The following illustration shows the major components of the Intel Server Compute Blade SBXD62 Control Panel Connector Control Panel Cable Heat S...

Страница 17: ...power on LED on the front of the server is lit If a power failure occurs the Intel Blade Server Chassis SBCE and then the blade server can start automatically when power is restored if the blade serve...

Страница 18: ...hown in the closed normal position in the following illustration To access the power control button you must open the control panel door Keyboard video mouse KVM select button Press this button to ass...

Страница 19: ...n Press this button to associate the shared removable media drives and USB ports with the blade server The LED on the button flashes while the request is being processed then is lit when the ownership...

Страница 20: ...to turn on or turn off the blade server Note The power control button has effect only if local power control is enabled for the blade server Local power control is enabled and disabled through the man...

Страница 21: ...itch block Switch block SW2 Table 1 Switch Block 2 SW2 Settings Switch number Description SW2 Switch block 2 has eight switches 1 BIOS backup page Off the BIOS starts from the Primary BIOS page On the...

Страница 22: ...ter the blade server is removed from the Intel Blade Server Chassis SBCE During that period of time you can relight the light path diagnostics LEDs for a maximum of 25 seconds or less depending on the...

Страница 23: ...LED Light path diagnostics LED CD111 Light path diagnostics switch SW4 Table 3 Light Path Diagnostics Panel LEDs LED error Action NMI Check error log for additional information Restart the blade serv...

Страница 24: ...uide Light path diagnostics button SW4 Press SW4 to find faults on the system board If the microprocessor or memory LED is lit reseat the component If the LED remains lit replace the defective compone...

Страница 25: ...ere you can grip the component to remove it from or install it in the blade server or open or close a latch Green on a component or an green label on or near a component indicates that the component c...

Страница 26: ...our movement Movement can cause static electricity to build up around you Handle the device carefully holding it by its edges or its frame Do not touch solder joints pins or exposed circuitry Do not l...

Страница 27: ...y you might need to reconfigure the blade server To remove the blade server complete the following steps 1 If the blade server is operating shut down the operating system then press the power control...

Страница 28: ...SBCE remove it see Removing the Blade Server from an Intel Blade Server Chassis SBCE on page 17 for instructions 3 Carefully lay the blade server down on a flat non conductive surface with the cover s...

Страница 29: ...h 4 Disconnect the control panel cable from the control panel connector 5 Pull the bezel assembly away from the blade server 6 Store the bezel assembly in a safe place Installing a SAS Hard Disk Drive...

Страница 30: ...Blade Server Chassis SBCE on page 17 for instructions 3 Carefully lay the blade server on a flat non conductive surface 4 Open the blade server cover see Opening the Blade Server Cover on page 18 for...

Страница 31: ...line memory modules DIMMs that the blade server supports and other information that you must consider when installing DIMMs The system board contains four DIMM connectors and supports two way memory i...

Страница 32: ...lade Server Chassis SBCE on page 17 for instructions 4 Carefully lay the blade server on a flat non conductive surface 5 Open the blade server cover see Opening the Blade Server Cover on page 18 for i...

Страница 33: ...e type of microprocessor that the server supports and other information that you must consider when installing a microprocessor Always install microprocessors that have the same cache size and type th...

Страница 34: ...tructions 6 Locate the microprocessor socket on the system board 7 Remove the two screws that secure the heat sink filler and then remove the filler from the microprocessor socket 8 Install the microp...

Страница 35: ...et or a system board d Center the microprocessor over the microprocessor socket Align the triangle on the corner of the microprocessor with the triangle on the corner of the socket and carefully press...

Страница 36: ...e heat sink b Align and place the heat sink on top of the microprocessor in the retention bracket grease side down Press firmly on the heat sink c Using a screwdriver secure the heat sink to the reten...

Страница 37: ...e Server Chassis SBCE the I O modules in I O module bays 3 and 4 must both be compatible with the expansion card All other expansion cards that are installed on other blade servers in the Intel Blade...

Страница 38: ...the following instructions If you replace the original lithium battery with a heavy metal battery or a battery with heavy metal components be aware of the following environmental consideration Batteri...

Страница 39: ...cial handling and installation instructions that come with the battery 3 Turn off the blade server and remove it from the Intel Blade Server Chassis SBCE see Installing the Blade Server in an Intel Bl...

Страница 40: ...task are in the following sections 1 Reinstall the blade server bezel assembly if you removed it see Removing the Blade Server Bezel Assembly on page 19 for information on installing the bezel assembl...

Страница 41: ...r is installed and closed or an expansion unit is installed Do not attempt to override this protection The following illustration shows how to close the blade server cover To close the blade server co...

Страница 42: ...tions that you want such as SAS drives or memory in the blade server 3 Select the bay for the blade server Notes a If the blade server has an expansion unit installed on it the blade server and expans...

Страница 43: ...which you removed it Some blade server configuration information and update options are established according to bay number Reinstalling a blade server into a different blade bay from the one from whi...

Страница 44: ...o selection buttons on the control panel the media tray select button and the keyboard video mouse select button See Understanding the Control Panel and LEDs on page 8 for information about these butt...

Страница 45: ...blade server Use it to select the boot protocol and other boot options and to select a power management option For information about using this utility program see Using the PXE Boot Agent Utility Pro...

Страница 46: ...nfiguration Setup Utility program some of those changes are reflected in the system information you cannot change settings directly in the system information Product Data Select this choice to view th...

Страница 47: ...consecutive failures to find a boot record You can enable a virus detection test that checks for changes in the boot record when the blade server starts This choice is on the full Configuration Setup...

Страница 48: ...eboot on System NMI option on the menu If you enable this option the blade server will automatically restart 60 seconds after the service processor issues a nonmaskable interrupt NMI to the blade serv...

Страница 49: ...to move the switch back to the previous position after the password is overridden See Using System Board Switches on page 11 for the location of switch block 2 Note Shut down the operating system tur...

Страница 50: ...nonvolatile memory and can be attached to e mail alerts Remote graphics console redirection Point to point protocol PPP support Remote power control Remote firmware update and access to critical serv...

Страница 51: ...ch server attached to each virtual LAN or subnet With failover you can configure more than one Ethernet controller from each server to attach to the same virtual LAN or subnet Either one of the integr...

Страница 52: ...you have a SCSI expansion unit in which SCSI hard disk drives are installed Two SAS hard disk drives in the blade server can be used to implement and manage RAID level 0 striping or RAID level 1 mirr...

Страница 53: ...es that POST detected a problem Error messages also appear during startup if POST detects a hardware configuration problem See POST Beep Code Descriptions on page 44 and the blade server Hardware Main...

Страница 54: ...nal information Beep codes for specific problems Additional beep codes are listed in the following table POST Error Messages The following table provides an abbreviated list of the error messages that...

Страница 55: ...port setting is correct 11xx Serial port error Make sure that the serial cable is connected correctly 1162 Serial port configuration conflict Start the Configuration Setup Utility program and make su...

Страница 56: ...memory are enabled The blade server might have automatically disabled a memory bank when it detected a problem or a memory bank might have been manually disabled Check the POST error log for error mes...

Страница 57: ...see the Intel Blade Server Chassis SBCE Hardware Maintenance Manual and Troubleshooting Guide on the Resource CD that came with your Intel Blade Server Chassis SBCE The screen is blank Make sure that...

Страница 58: ...vice Wrong characters appear on the screen If the wrong language is displayed update the firmware or operating system with the correct language in the blade server that has ownership of the monitor If...

Страница 59: ...stem List located on http support intel com for a list of compatible hardware You followed the installation instructions that come with the expansion card The option is installed correctly You have no...

Страница 60: ...r the blade server is defective or the LED information panel is loose or defective e Local power control for the blade server is enabled use the management module Web interface to verify or the blade...

Страница 61: ...el Blade Server Chassis SBCE see Turning off the Blade Server on page 7 and Removing the Blade Server from an Intel Blade Server Chassis SBCE on page 17 2 Place the blade server on a flat static prote...

Страница 62: ...ED is not lit when the light path diagnostics button is pressed no power is available to light the blade error LEDs and they will be unable to provide any diagnostic information The following table li...

Страница 63: ...ade Server Chassis SBCE has failed If it has replace the blower Make sure that the room temperature is not too high see Intel Server Compute Blade SBXD62 Specifications on page 3 for temperature infor...

Страница 64: ...54 Intel Server Compute Blade SBXD62 Installation and User s Guide...

Страница 65: ...Product is defective transportation charges for the return of Product to buyer within the USA will be paid by Intel For all other locations the warranty excludes all costs of shipping customs clearanc...

Страница 66: ...y costs of recovering reprogramming or reproducing any program or data stored in or used with a system containing this product Some jurisdictions do not allow the exclusion or limitation of incidental...

Страница 67: ...s for the remainder of the original warranty period Telephone Support If you cannot find the information you need on Intel s World Wide Web site http www intel com call your local distributor or an In...

Страница 68: ...58 Intel Server Compute Blade SBXD62 Installation and User s Guide...

Страница 69: ...e This blade server product when correctly integrated per this guide complies with the following safety and electromagnetic compatibility EMC regulations Intended Application This product was evaluate...

Страница 70: ...ions Europe EN55024 Immunity Europe EN61000 3 2 Harmonics Europe EN61000 3 3 Voltage Flicker Europe CE EMC Directive 89 336 EEC Europe VCCI Emissions Japan AS NZS 3548 Emissions Australia New Zealand...

Страница 71: ...able 1 Product Regulatory Compliance Markings Regulatory Compliance Region Marking cULus Listing Marks USA Canada CE Mark Europe FCC Marking Class A USA EMC Marking Class A Canada VCCI Marking Class A...

Страница 72: ...ence will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user...

Страница 73: ...ES 003 of the Canadian Department of Communications Europe CE Declaration of Conformity This product has been tested in accordance to and complies with the Low Voltage Directive 73 23 EEC and EMC Dire...

Страница 74: ...the use of banned substances in accordance with the European Directive 2002 95 EC Compliance is based on declaration that materials banned in the RoHS Directive are either 1 below all applicable subs...

Страница 75: ...ecified in this guide Use of other products components will void the UL Listing and other regulatory approvals of the product and may result in noncompliance with product regulations in the region s i...

Страница 76: ...are susceptible to electrical storms we recommend you plug your system into a surge suppressor and disconnect telecommunication lines to your modem during an electrical storm Provided with a properly...

Страница 77: ...er cord was not provided with your product purchase one that is approved for use in your country Caution To avoid electrical shock or fire check the power cord s that will be used with the product as...

Страница 78: ...he system without the fan guard in place Rack Mount Warnings The equipment rack must be anchored to an unmovable support to prevent it from tipping when a server or piece of equipment is extended from...

Страница 79: ...Caution Carefully route cables as directed to minimize airflow blockage and cooling problems For proper cooling and airflow operate the system only with the chassis covers installed Operating the sys...

Страница 80: ...derer Produkte oder Komponenten f hrt zum Erl schen der UL Zulassung und anderer Genehmigungen f r das Produkt Dadurch kann das Produkt gegen Produktbestimmungen versto en die im Verkaufsland gelten S...

Страница 81: ...tions oder Ersch tterungsquellen Abgeschirmt von starken elektromagnetischen Feldern die durch elektrische Ger te erzeugt werden In gewittergef hrdeten Gebieten sollten Sie das System an einen berspan...

Страница 82: ...tet werden k nnen ffnen Sie das Netzteil nicht Im Netzteil bestehen gef hrliche Spannungen Str me und Energiequellen Schicken Sie das Ger t f r Wartungsarbeiten an den Hersteller zur ck Wenn Sie ein h...

Страница 83: ...befestigungselementen F hren Sie keine Arbeiten im Netzteil aus Das Netzteil enth lt keine f r den Benutzer wartungsbed rftigen Teile Schicken Sie das Ger t f r Wartungsarbeiten an den Hersteller zur...

Страница 84: ...lle darin eingebauten Ger te ordnungsgem geerdet sein Elektrostatische Entladungen ESD Vorsicht Elektrostatische Entladungen k nnen zur Besch digung von Festplatten Platinen und anderen Komponenten f...

Страница 85: ...das System nur mit angebrachten Geh useabdeckungen betrieben werden Die Inbetriebnahme des Systems ohne Abdeckung kann zur Besch digung von Systemkomponenten f hren So bringen Sie die Abdeckung wiede...

Страница 86: ...pprobations r glementaires du produit et le produit peut ne pas tre conforme aux autres lois et r glementations locales applicables au produit S curit avertissements et mises en garde Pour viter de vo...

Страница 87: ...s sources de chaleur telles que la lumi re directe du soleil et les radiateurs l cart des sources de vibration ou des chocs physiques Isol des champs lectromagn tiques importants produits par des appa...

Страница 88: ...bl me Lorsque vous remplacez un bloc d alimentation chaud d branchez le cordon du bloc d alimentation en cours de remplacement avant de le retirer du serveur Pour viter tout risque d lectrocution mett...

Страница 89: ...u bloc d alimentation Il ne contient aucune pi ce r parable Renvoyez le au fabricant en cas de probl me Mettez le serveur hors tension et d branchez tous les cordons d alimentation avant d ajouter ou...

Страница 90: ...le rack doivent tre correctement reli s la terre D charges lectrostatiques ESD Attention Les d charges lectrostatiques ESD peuvent endommager les lecteurs de disque dur les cartes et d autres pi ces...

Страница 91: ...obl mes de refroidissement Afin de permettre une ventilation et un refroidissement corrects ne mettez le syst me en marche que lorsque les panneaux du ch ssis sont en place L utilisation du syst me sa...

Страница 92: ...onentes anular la homologaci n UL y otras certificaciones oficiales del producto pudiendo dejar de ser compatible con las normativas locales de los pa ses en los que se comercializa Advertencias y pre...

Страница 93: ...Bien ventilada y alejada de fuentes de calor incluida la luz solar directa y los radiadores Alejada de fuentes de vibraci n o de golpes f sicos Aislada de campos electromagn ticos producidos por dispo...

Страница 94: ...niveles de tensi n corriente y energ a peligrosos Devu lvala al fabricante para repararla Al reemplazar una fuente de alimentaci n de conexi n en funcionamiento desenchufe el cable de alimentaci n de...

Страница 95: ...alimentaci n No hay elementos en la fuente de alimentaci n que usted pueda reparar y utilizar Devu lvala al fabricante para repararla Apague el servidor y desconecte todos los cables de alimentaci n a...

Страница 96: ...talar una conexi n a tierra apropiada para el rack y para cada pieza del equipo instalada en el mismo Descarga electrost tica ESD Precauci n Las descargas electrost ticas pueden da ar las unidades de...

Страница 97: ...ilaci n y de refrigeraci n Para conseguir una refrigeraci n y corriente de aire adecuadas compruebe que cuando sistema est funcionando las cubiertas de la carcasa est n instaladas Si utiliza el sistem...

Страница 98: ...88 Intel Server Compute Blade SBXD62 Installation and User s Guide Intel Intel Intel Web UL...

Страница 99: ...Intel Server Compute Blade SBXD62 Installation and User s Guide 89 ITE ITE 5V...

Страница 100: ...90 Intel Server Compute Blade SBXD62 Installation and User s Guide...

Страница 101: ...Intel Server Compute Blade SBXD62 Installation and User s Guide 91 ESD ESD ESD ESD ESD...

Страница 102: ...92 Intel Server Compute Blade SBXD62 Installation and User s Guide...

Страница 103: ...card exchange rate plus applicable taxes Intel reserves the right to change the pricing for telephone support at any time without notice For an updated support contact list see http www intel com supp...

Страница 104: ...nmar 63 2 636 9796 via Philippines New Zealand 0800 444 365 Pakistan 632 63684 15 IDD via Philippines Philippines 1 800 1 651 0117 Singapore 65 6213 1311 Taiwan 2 2545 1640 Thailand 1 800 631 0003 Vie...

Страница 105: ...800 843 4481 Pacifictel Contact AT T USA at 1 800 225 528 Once connected dial 800 843 4481 Guatemala Contact AT T USA at 99 99 190 Once connected dial 800 843 4481 Mexico Contact AT T USA at 001 800 4...

Страница 106: ...96 Intel Server Compute Blade SBXD62 Installation and User s Guide...

Страница 107: ...d near the equipment and shall be easily accessible SAFETY STEPS Whenever you remove the chassis covers to access the inside of the system follow these steps 1 Turn off all peripheral devices connecte...

Страница 108: ...hassis parts Contact should be made with care Consider wearing protective gloves Danger of explosion if the battery is incorrectly replaced Replace only with the same or equivalent type recommended by...

Страница 109: ...Sie jedes Wechselstrom Netzkabel aus der Steckdose bzw dem Netzger t um den Stromanschlu des Systems zu unterbrechen SICHERHEISMASSNAHMEN Immer wenn Sie die Geh useabdeckung abnehmen um an das Systemi...

Страница 110: ...igen Um die Abdeckung wieder anzubringen 1 Vergewissern Sie sich da Sie keine Werkzeuge oder Teile im Innern des Systems zur ckgelassen haben 2 berpr fen Sie alle Kabel Zusatzkarten und andere Kompone...

Страница 111: ...ausgesetzt sein keine starken von elektrischen Ger ten erzeugten elektromagnetischen Felder aufweisen in Regionen in denen elektrische St rme auftreten mit einem berspannungsschutzger t verbunden sei...

Страница 112: ...our acc der l int rieur du syst me suivez les consignes suivantes 1 Mettez hors tension tous les p riph riques connect s au syst me 2 Mettez le syst me hors tension en mettant l interrupteur g n ral e...

Страница 113: ...ttention aux broches aigu s des cartes et aux bords tranchants du capot Nous vous recommandons l usage de gants de protection Danger d explosion si la batterie n est pas remont e correctement Remplace...

Страница 114: ...extraiga la tapa del chasis para acceder al interior del sistema siga las siguientes instrucciones 1 Apague todos los dispositivos perif ricos conectados al sistema 2 Apague el sistema presionando el...

Страница 115: ...nviene tener en cuenta que en el chasis o en el tablero puede haber piezas cortantes o punzantes Por ello se recomienda precauci n y el uso de guantes protectores Existe peligro de explosi n si la pil...

Страница 116: ...per accedere all interno del sistema seguire i seguenti passi 1 Spegnere tutti i dispositivi periferici collegati al sistema 2 Spegnere il sistema usando il pulsante spento acceso dell interruttore de...

Страница 117: ...urriscaldati Fare attenzione alla presenza di piedini appuntiti e parti taglienti sulle schede e sul telaio consigliabile l uso di guanti di protezione Esiste il pericolo di un esplosione se la pila n...

Страница 118: ...108 Intel Server Compute Blade SBXD62 Installation and User s Guide...