background image

Intel® Server Compute Blade SBXD132 Installation and User’s Guide

27

8. Center the microprocessor over the microprocessor socket. Align the triangle on the 

corner of the microprocessor with the triangle on the corner of the socket and 

carefully place the microprocessor into the socket. 

Caution:

--

Do not press the microprocessor into the socket.

--

Make sure that the microprocessor is oriented and aligned correctly in the 

socket before you try to close the microprocessor retainer.

f. Carefully close the microprocessor retainer.
g. Rotate the locking lever on the microprocessor socket to the closed and locked 

position. Make sure that the lever is secured in the locked position by the tab on 

the microprocessor socket.

9. Install a heat sink on the microprocessor. 

Caution:

--

Do not set down the heat sink after you remove the plastic cover.   

--

Do not touch the thermal grease on the bottom of the heat sink. Touching the 

thermal grease will contaminate it. If the thermal grease on the 

microprocessor or heat sink becomes contaminated, contact your service 

technician. 

a. Remove the plastic protective cover from the bottom of the heat sink.
b. Make sure that the thermal material is still on the bottom of the heat sink; then, 

align and place the heat sink on top of the microprocessor in the retention bracket, 

thermal material side down. Press firmly on the heat sink.

c. Align the two screws on the heat sink with the holes on the heat-sink retention 

module.

d. Press firmly on the captive screws and tighten them with a screwdriver, alternating 

between screws until they are tight. If possible, each screw should be rotated two 

full rotations at a time. Repeat until the screws are tight. Do not overtighten the 

screws by using excessive force. If you are using a torque wrench, tighten the 

screws to 8.5 to 13 Newton-meters (Nm) (6.3 to 9.6 foot-pounds).

10. If you have other options to install or remove, do so now; otherwise, go to 

“Completing the Installation” on page 32

.

Heat sink

Thermal grease

Содержание SBXD132 - Server Compute Blade

Страница 1: ...Intel Server Compute Blade SBXD132 Installation and User s Guide A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies Products Intel Order Number D64326 002...

Страница 2: ...ications and product descriptions at any time without notice Intel server boards contain a number of high density VLSI and power delivery components that need adequate airflow for cooling Intel s own...

Страница 3: ...the Blade Server 9 Turning off the Blade Server 9 Understanding the Control Panel and LEDs 10 Blade Server Connectors 12 Installing Options 15 Installation Guidelines 15 System Reliability Guidelines...

Страница 4: ...47 Installing a Hot swap SAS Hard Disk Drive 50 Completing the Installation 51 Configuring the Expansion Unit RAID Array 52 Using the Adaptec RAID Configuration Utility Program 52 Using the ServeRAID...

Страница 5: ...apan 77 BSMI Taiwan 77 Korean Compliance RRL 78 Restriction of Hazardous Substances RoHS Compliance 78 End of Life Product Recycling 78 C Getting Help 79 World Wide Web 79 Telephone 79 U S and Canada...

Страница 6: ...tion d un emplacement 95 Pratiques de manipulation de l quipement 95 D charges lectrostatiques ESD 98 Autres risques 99 Espa ol 100 Informaci n de seguridad del servidor 100 Advertencias y precaucione...

Страница 7: ...geh usen auf der Intel Server Deployment Toolkit CD oder unter http support intel com support motherboards server sb cs 010770 htm Consignes de s curit Lisez attention toutes les consignes de s curit...

Страница 8: ...works and modems attached to the blade system before opening it Otherwise personal injury or equipment damage can result Electrostatic discharge ESD and ESD protection ESD can damage disk drives board...

Страница 9: ...operating system To download the latest device drivers go to http support intel com support The blade server comes with a limited warranty For information about the terms of the warranty and getting s...

Страница 10: ...mentation also comes with the blade server Hardware Maintenance and Troubleshooting Guide This document is in Portable Document Format PDF on the Resource CD It contains information to help you solve...

Страница 11: ...D requires the following minimum hardware and software Microsoft Windows NT 4 0 with Service Pack 3 or later Windows 2000 or Red Hat Linux 100 MHz microprocessor 32 MB of RAM Adobe Acrobat Reader 3 0...

Страница 12: ...al memory in the system board Additional memory support when an optional Intel Blade Server Memory and I O Expansion Blade is installed Drives Support for two internal small form factor Serial Attache...

Страница 13: ...using the latest microprocessor technology The blade server supports up to two dual core quad core Intel Xeon processor microprocessors Integrated network support The blade server comes with two integ...

Страница 14: ...y is enforced when the initial power is applied to the SBCE unit or when a blade server is inserted into the SBCE unit You can configure and monitor the power environment by using the management modul...

Страница 15: ...self test BIST during power on self test POST Microprocessor presence detection Microprocessor serial number access Power policy support Power on self test POST Predictive Failure Analysis PFA alerts...

Страница 16: ...the SBCE unit and remove the cover to see the components The following illustration shows the major components of the blade server Control panel connector Control Panel Cable Bezel Heat sink Micropro...

Страница 17: ...D on the front of the blade server is lit See Understanding the Control Panel and LEDs on page 10 for the power on LED states If a power failure occurs the SBCE unit and then the blade server can star...

Страница 18: ...functioning you can press and hold the power control button for more than 4 seconds to turn off the blade server The management module can turn off the blade server If the system is not operating corr...

Страница 19: ...f you install a supported Microsoft Windows operating system on the blade server while it is not the current owner of the keyboard video and mouse a delay of up to 1 minute occurs the first time that...

Страница 20: ...blade server Local power control is enabled and disabled through the management module Web interface Power on LED This green LED indicates the power status of the blade server in the following manner...

Страница 21: ...and User s Guide 13 The following illustration shows components for the optional Intel Blade Server Memory and I O Expansion Blade DIMM8 J19 Blade expansion option J14 I O expansion option J17 I O exp...

Страница 22: ...14 Intel Server Compute Blade SBXD132 Installation and User s Guide...

Страница 23: ...parts in a safe place Back up all important data before you make changes to disk drives Before you remove a blade server from the SBCE unit you must shut down the operating system and turn off the bla...

Страница 24: ...it to an unpainted metal part of the SBCE unit or any unpainted metal surface on any other grounded rack component in the rack in which you are installing the device for at least 2 seconds This drain...

Страница 25: ...nd the blade server control panel door to turn off the blade server see Turning off the Blade Server on page 9 for more information Caution Wait at least 30 seconds until the hard disk drives stop spi...

Страница 26: ...e installing the blade server Removing an Expansion Unit The following illustration shows how to remove an expansion unit from a blade server To remove the expansion unit complete the following steps...

Страница 27: ...bly The following illustration shows how to remove the bezel assembly To remove the blade server bezel assembly complete the following steps 1 Read the safety information beginning on page vii and Ins...

Страница 28: ...ard occupies the same area as the second hard disk drive To install a SAS hard disk drive complete the following steps 1 Read the safety information beginning on page vii and Installation Guidelines o...

Страница 29: ...AS hard disk drive complete the following steps 1 Read the safety information beginning on page vii and Installation Guidelines on page 15 2 Shutdown the operating system turn off the blade server and...

Страница 30: ...ade servers with no Memory and I O Expansion Blade when you install memory you must install a pair of matched DIMMs Install the DIMMs in the following order To set up a non mirrored memory configurati...

Страница 31: ...program When you restart the blade server it displays a message indicating that the memory configuration has changed Start the Configuration Setup Utility program and select Save Settings see Configu...

Страница 32: ...ng clips the DIMM has not been correctly installed In this case open the retaining clips and remove the DIMM then reinsert the DIMM 10 If you have other options to install or remove do so now otherwis...

Страница 33: ...ket must contain a microprocessor heat sink filler sometimes called a microprocessor baffle The microprocessor speeds are automatically set for this server therefore you do not have to set any micropr...

Страница 34: ...ing lever on the microprocessor socket from its closed and locked position until it stops in the fully open position approximately a 135 angle as shown c Rotate the microprocessor retainer on the micr...

Страница 35: ...heat sink Touching the thermal grease will contaminate it If the thermal grease on the microprocessor or heat sink becomes contaminated contact your service technician a Remove the plastic protective...

Страница 36: ...card to a blade server installed in a SBCE unit the I O modules in I O module bays 3 and 4 on the SBCE unit must both be compatible with the expansion card All other expansion cards that are installed...

Страница 37: ...ed and you are installing the expansion card on the system board remove the expansion blade see Removing an Expansion Unit on page 18 6 Touch the static protective package that contains the expansion...

Страница 38: ...rm factor expansion card To install a standard form factor expansion card complete the following steps 1 Read the safety information beginning on page vii and Installation Guidelines on page 15 2 Shut...

Страница 39: ...ion of the expansion card see the documentation that comes with the expansion card 11 If you have other options to install or remove do so now otherwise go to Completing the Installation on page 32 In...

Страница 40: ...ansion unit closed then use the extraction device to fully seat the expansion unit on the system board These extraction devices can be of several types including thumb screws or levers If the expansio...

Страница 41: ...ver Note If you have just connected the power cords of the SBCE unit to electrical outlets you must wait until the power on LED on the blade server flashes slowly before you press the power control bu...

Страница 42: ...removed the blade bezel assembly replace it now see Installing the Blade Server Bezel Assembly on page 33 for instructions 3 If a Memory and I O Expansion Blade is not installed on the blade server m...

Страница 43: ...ives or memory in the blade server 3 Select the bay for the blade server at least one blade bay is required Notes When any blade server or option is in blade bays 7 through 14 power modules must be pr...

Страница 44: ...t you can save the new configuration settings See Using the Configuration Setup Utility program on page 57 for more information about the Configuration Setup Utility program Some options have device d...

Страница 45: ...standard form factor and small form factor cards as well as a storage expansion unit such as the Intel Blade Storage Expansion Module see Intel Blade Storage Expansion Module for the Intel Server Com...

Страница 46: ...38 Intel Server Compute Blade SBXD132 Installation and User s Guide...

Страница 47: ...S hard disk drives in the expansion unit and up to two hard disk drives that are installed in the host blade server The expansion unit also supports up to two I O expansion cards standard form factor...

Страница 48: ...keep static sensitive devices in their static protective packages until you are ready to install them To reduce the possibility of damage from electrostatic discharge observe the following precautions...

Страница 49: ...ardous procedure step or situation Danger These statements indicate situations that can be potentially lethal or extremely hazardous to you A danger statement is placed just before the description of...

Страница 50: ...ove the cover from the connector 6 Touch the static protective package that contains the expansion unit to any unpainted metal surface on the SBCE unit or any unpainted metal surface on another ground...

Страница 51: ...he expansion unit cover 1 Read the Safety information beginning on page vii and Installation Guidelines on page 39 2 Orient the cover over the expansion unit 3 Lower the cover so that the slots at the...

Страница 52: ...and turn off the blade server then remove the combined blade server and expansion unit from the SBCE unit see the documentation that comes with the blade server for more information 3 Carefully lay t...

Страница 53: ...it shut down the operating system and turn off the blade server then remove the combined blade server and expansion unit from the SBCE unit see the documentation that comes with the blade server for m...

Страница 54: ...ttery holder 3 Insert the two push pins until they lock the battery into place in the battery holder 4 Touch the static protective package that contains the ServeRAID SAS Controller AB256BSE to any un...

Страница 55: ...ported I O expansion cards in the expansion unit Before installing an I O expansion card consider the following information The expansion unit supports two different form factors of I O expansion card...

Страница 56: ...surface on the SBCE unit or any unpainted metal surface on any other grounded rack component then remove the expansion card from the package 4 To install a small form factor expansion card complete th...

Страница 57: ...ors of the expansion unit installing a card in the connectors closest to the front of the expansion unit is similar a Locate the expansion card connectors and orient the expansion card above them b Sl...

Страница 58: ...drive bay 1 Read the Safety information beginning on page vii and Installation Guidelines on page 39 2 Select the hot swap bay in which you want to install the hard disk drive 3 Firmly grasp the driv...

Страница 59: ...sure that the SBCE unit has the required number of power modules present to supply power to the blade bay in which the expansion unit is installed For additional information see the documentation tha...

Страница 60: ...prompt Press CTRL A for Adaptec RAID Configuration Utility appears press Ctrl A 3 To select a choice from the menu use the arrow keys to highlight it and press Enter Adaptec RAID Configuration Utilit...

Страница 61: ...ration Utility 3 From the Main menu select Manage Arrays 4 Select an array and press Enter 5 To exit from the program press Esc Using the ServeRAID Manager Program The ServeRAID Support CD contains th...

Страница 62: ...xpansion unit error amber A system board error has occurred in the expansion unit Check for error LEDs that are lit on the expansion unit system board Reseat the following components 1 SAS controller...

Страница 63: ...stallation and User s Guide 55 SAS controller error amber An error has occurred in the SAS controller 1 Reseat the SAS controller 2 Replace the SAS controller 3 Replace the expansion unit Lit light pa...

Страница 64: ...56 Intel Server Compute Blade SBXD132 Installation and User s Guide...

Страница 65: ...ot agent utility program is part of the BIOS code in the blade server Use it to select the boot protocol and other boot options and to select a power management option For information about using this...

Страница 66: ...ystem information you cannot change settings directly in the system information Product Data Select this choice to view the machine type and model of the blade server the serial number and the revisio...

Страница 67: ...ve or keyboard You can enable or disable the PXE option for either of the integrated Gigabit Ethernet controllers The default setting is Planar Ethernet 1 which enables the PXE option for the first Et...

Страница 68: ...u can also select this choice to enable or disable hyper threading and adjust microprocessor performance settings If enabled hyper threading will only be active if it is supported by your operating sy...

Страница 69: ...ing the PXE Boot Agent Utility Program Use the Preboot Execution Environment PXE boot agent utility program to select the boot protocol and other boot options and to select a power management option N...

Страница 70: ...ollers for the blade server operating system However you must install a device driver to enable the blade server operating system to address the Ethernet controllers For device drivers and information...

Страница 71: ...on card in the blade server communications from the expansion card are routed to I O module bays 3 and 4 You can verify which controller on the card is routed to which I O module bay by performing the...

Страница 72: ...server is the owner of the keyboard video and mouse and watch the monitor screen 2 When the Press Ctrl C to start LSI Logic Configuration Utility prompt appears press Ctrl C 3 Use the arrow keys to se...

Страница 73: ...ia drives The Intel Blade Server Chassis SBCE uses USB for internal communication with these devices 2 Some operating systems enable you to select the type of mouse that is being used If you are offer...

Страница 74: ...66 Intel Server Compute Blade SBXD132 Installation and User s Guide...

Страница 75: ...er reinstall the blade server in the SBCE unit and then restart the blade server If the blade server does not start after you have performed the preceding actions see the Intel Server Compute Blade SB...

Страница 76: ...formation Note If you are unable to find the system error logs in the blade server firmware code view the system event log in the chassis management module Light path diagnostics Use light path diagno...

Страница 77: ...Product is defective transportation charges for the return of Product to buyer within the USA will be paid by Intel For all other locations the warranty excludes all costs of shipping customs clearan...

Страница 78: ...y costs of recovering reprogramming or reproducing any program or data stored in or used with a system containing this product Some jurisdictions do not allow the exclusion or limitation of incidental...

Страница 79: ...s for the remainder of the original warranty period Telephone Support If you cannot find the information you need on Intel s World Wide Web site http www intel com call your local distributor or an In...

Страница 80: ...72 Intel Server Compute Blade SBXD132 Installation and User s Guide...

Страница 81: ...ce This blade server product when correctly integrated per this guide complies with the following safety and electromagnetic compatibility EMC regulations Intended Application This product was evaluat...

Страница 82: ...ions Europe EN55024 Immunity Europe EN61000 3 2 Harmonics Europe EN61000 3 3 Voltage Flicker Europe CE EMC Directive 89 336 EEC Europe VCCI Emissions Japan AS NZS 3548 Emissions Australia New Zealand...

Страница 83: ...able 1 Product Regulatory Compliance Markings Regulatory Compliance Region Marking cULus Listing Marks USA Canada CE Mark Europe FCC Marking Class A USA EMC Marking Class A Canada VCCI Marking Class A...

Страница 84: ...rence will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the use...

Страница 85: ...ES 003 of the Canadian Department of Communications Europe CE Declaration of Conformity This product has been tested in accordance to and complies with the Low Voltage Directive 73 23 EEC and EMC Dire...

Страница 86: ...t the use of banned substances in accordance with the European Directive 2002 95 EC Compliance is based on declaration that materials banned in the RoHS Directive are either 1 below all applicable sub...

Страница 87: ...card exchange rate plus applicable taxes Intel reserves the right to change the pricing for telephone support at any time without notice For an updated support contact list see http www intel com sup...

Страница 88: ...nmar 63 2 636 9796 via Philippines New Zealand 0800 444 365 Pakistan 632 63684 15 IDD via Philippines Philippines 1 800 1 651 0117 Singapore 65 6213 1311 Taiwan 2 2545 1640 Thailand 1 800 631 0003 Vie...

Страница 89: ...800 843 4481 Pacifictel Contact AT T USA at 1 800 225 528 Once connected dial 800 843 4481 Guatemala Contact AT T USA at 99 99 190 Once connected dial 800 843 4481 Mexico Contact AT T USA at 001 800 4...

Страница 90: ...82 Intel Server Compute Blade SBXD132 Installation and User s Guide...

Страница 91: ...pecified in this guide Use of other products components will void the UL Listing and other regulatory approvals of the product and may result in noncompliance with product regulations in the region s...

Страница 92: ...t are susceptible to electrical storms we recommend you plug your system into a surge suppressor and disconnect telecommunication lines to your modem during an electrical storm Provided with a properl...

Страница 93: ...er cord was not provided with your product purchase one that is approved for use in your country Caution To avoid electrical shock or fire check the power cord s that will be used with the product as...

Страница 94: ...the system without the fan guard in place Rack Mount Warnings The equipment rack must be anchored to an unmovable support to prevent it from tipping when a server or piece of equipment is extended fro...

Страница 95: ...Caution Carefully route cables as directed to minimize airflow blockage and cooling problems For proper cooling and airflow operate the system only with the chassis covers installed Operating the sys...

Страница 96: ...derer Produkte oder Komponenten f hrt zum Erl schen der UL Zulassung und anderer Genehmigungen f r das Produkt Dadurch kann das Produkt gegen Produktbestimmungen versto en die im Verkaufsland gelten S...

Страница 97: ...tions oder Ersch tterungsquellen Abgeschirmt von starken elektromagnetischen Feldern die durch elektrische Ger te erzeugt werden In gewittergef hrdeten Gebieten sollten Sie das System an einen berspan...

Страница 98: ...tet werden k nnen ffnen Sie das Netzteil nicht Im Netzteil bestehen gef hrliche Spannungen Str me und Energiequellen Schicken Sie das Ger t f r Wartungsarbeiten an den Hersteller zur ck Wenn Sie ein h...

Страница 99: ...befestigungselementen F hren Sie keine Arbeiten im Netzteil aus Das Netzteil enth lt keine f r den Benutzer wartungsbed rftigen Teile Schicken Sie das Ger t f r Wartungsarbeiten an den Hersteller zur...

Страница 100: ...lle darin eingebauten Ger te ordnungsgem geerdet sein Elektrostatische Entladungen ESD Vorsicht Elektrostatische Entladungen k nnen zur Besch digung von Festplatten Platinen und anderen Komponenten f...

Страница 101: ...f das System nur mit angebrachten Geh useabdeckungen betrieben werden Die Inbetriebnahme des Systems ohne Abdeckung kann zur Besch digung von Systemkomponenten f hren So bringen Sie die Abdeckung wied...

Страница 102: ...approbations r glementaires du produit et le produit peut ne pas tre conforme aux autres lois et r glementations locales applicables au produit S curit avertissements et mises en garde Pour viter de v...

Страница 103: ...s sources de chaleur telles que la lumi re directe du soleil et les radiateurs l cart des sources de vibration ou des chocs physiques Isol des champs lectromagn tiques importants produits par des appa...

Страница 104: ...bl me Lorsque vous remplacez un bloc d alimentation chaud d branchez le cordon du bloc d alimentation en cours de remplacement avant de le retirer du serveur Pour viter tout risque d lectrocution mett...

Страница 105: ...u bloc d alimentation Il ne contient aucune pi ce r parable Renvoyez le au fabricant en cas de probl me Mettez le serveur hors tension et d branchez tous les cordons d alimentation avant d ajouter ou...

Страница 106: ...s le rack doivent tre correctement reli s la terre D charges lectrostatiques ESD Attention Les d charges lectrostatiques ESD peuvent endommager les lecteurs de disque dur les cartes et d autres pi ces...

Страница 107: ...robl mes de refroidissement Afin de permettre une ventilation et un refroidissement corrects ne mettez le syst me en marche que lorsque les panneaux du ch ssis sont en place L utilisation du syst me s...

Страница 108: ...ponentes anular la homologaci n UL y otras certificaciones oficiales del producto pudiendo dejar de ser compatible con las normativas locales de los pa ses en los que se comercializa Advertencias y pr...

Страница 109: ...Bien ventilada y alejada de fuentes de calor incluida la luz solar directa y los radiadores Alejada de fuentes de vibraci n o de golpes f sicos Aislada de campos electromagn ticos producidos por disp...

Страница 110: ...niveles de tensi n corriente y energ a peligrosos Devu lvala al fabricante para repararla Al reemplazar una fuente de alimentaci n de conexi n en funcionamiento desenchufe el cable de alimentaci n de...

Страница 111: ...alimentaci n No hay elementos en la fuente de alimentaci n que usted pueda reparar y utilizar Devu lvala al fabricante para repararla Apague el servidor y desconecte todos los cables de alimentaci n...

Страница 112: ...stalar una conexi n a tierra apropiada para el rack y para cada pieza del equipo instalada en el mismo Descarga electrost tica ESD Precauci n Las descargas electrost ticas pueden da ar las unidades de...

Страница 113: ...tilaci n y de refrigeraci n Para conseguir una refrigeraci n y corriente de aire adecuadas compruebe que cuando sistema est funcionando las cubiertas de la carcasa est n instaladas Si utiliza el siste...

Страница 114: ...106 Intel Server Compute Blade SBXD132 Installation and User s Guide I nt el I nt el I nt el Web UL...

Страница 115: ...Intel Server Compute Blade SBXD132 Installation and User s Guide 107 ITE ITE 5V...

Страница 116: ...108 Intel Server Compute Blade SBXD132 Installation and User s Guide...

Страница 117: ...Intel Server Compute Blade SBXD132 Installation and User s Guide 109 ESD ESD ESD ESD ESD...

Страница 118: ...110 Intel Server Compute Blade SBXD132 Installation and User s Guide...

Страница 119: ...ed near the equipment and shall be easily accessible SAFETY STEPS Whenever you remove the chassis covers to access the inside of the system follow these steps 1 Turn off all peripheral devices connect...

Страница 120: ...chassis parts Contact should be made with care Consider wearing protective gloves Danger of explosion if the battery is incorrectly replaced Replace only with the same or equivalent type recommended b...

Страница 121: ...Sie jedes Wechselstrom Netzkabel aus der Steckdose bzw dem Netzger t um den Stromanschlu des Systems zu unterbrechen SICHERHEISMASSNAHMEN Immer wenn Sie die Geh useabdeckung abnehmen um an das System...

Страница 122: ...digen Um die Abdeckung wieder anzubringen 1 Vergewissern Sie sich da Sie keine Werkzeuge oder Teile im Innern des Systems zur ckgelassen haben 2 berpr fen Sie alle Kabel Zusatzkarten und andere Kompon...

Страница 123: ...ausgesetzt sein keine starken von elektrischen Ger ten erzeugten elektromagnetischen Felder aufweisen in Regionen in denen elektrische St rme auftreten mit einem berspannungsschutzger t verbunden sei...

Страница 124: ...our acc der l int rieur du syst me suivez les consignes suivantes 1 Mettez hors tension tous les p riph riques connect s au syst me 2 Mettez le syst me hors tension en mettant l interrupteur g n ral e...

Страница 125: ...ttention aux broches aigu s des cartes et aux bords tranchants du capot Nous vous recommandons l usage de gants de protection Danger d explosion si la batterie n est pas remont e correctement Remplace...

Страница 126: ...extraiga la tapa del chasis para acceder al interior del sistema siga las siguientes instrucciones 1 Apague todos los dispositivos perif ricos conectados al sistema 2 Apague el sistema presionando el...

Страница 127: ...onviene tener en cuenta que en el chasis o en el tablero puede haber piezas cortantes o punzantes Por ello se recomienda precauci n y el uso de guantes protectores Existe peligro de explosi n si la pi...

Страница 128: ...per accedere all interno del sistema seguire i seguenti passi 1 Spegnere tutti i dispositivi periferici collegati al sistema 2 Spegnere il sistema usando il pulsante spento acceso dell interruttore de...

Страница 129: ...urriscaldati Fare attenzione alla presenza di piedini appuntiti e parti taglienti sulle schede e sul telaio consigliabile l uso di guanti di protezione Esiste il pericolo di un esplosione se la pila n...

Страница 130: ...122 Intel Server Compute Blade SBXD132 Installation and User s Guide...

Отзывы: