Intel
®
Server Board S5000PSL
7
Configuration Jumpers
Jumper Name
Pins
What Happens at System Reset
BIOS Bank Select
(J1C3)
1 - 2
Bank 0: Boot to an alternate BIOS.
2 - 3
Boot from the standard BIOS. These pins should be
jumpered for normal operation.
CMOS Clear
(J1D1)
1 - 2
Protect CMOS: these pins should be jumpered for normal
operation.
2 - 3
Erase CMOS: If these pins are jumpered for 5 to 10
seconds, the CMOS settings will be cleared on the next
server reset. These pins should not be jumpered for
normal operation.
Note:
The server does not need to be reset with the
jumpers on these pins for the CMOS to be
cleared. To clear the CMOS: Power down the
server. Place the jumper on pins 2 - 3 for 5 to 10
seconds. Moving the jumper back to pins 1 - 2.
Power on the server.
AF000422
3
2
CMOS Clear
3
2
Password Clear
J1E3
J1D1
Disable
Enable
3
2
BMC Force Update
J1D2
Disable
Enable
BIOS Bank Select
J1C3
3
2
Bank 0
Normal
Operation
Protect
Clear