2.2
System Level Environmental Limits
The following table defines the system level operating and non-operating environmental limits.
Table 3. System Environmental Limits Summary
Parameter
Limits
Temperature
Operating
ASHRAE Class A2 – Continuous Operation. 10ºC to 35ºC
1
(50ºF to 95ºF)
with the maximum rate of change not to exceed 10°C per hour
ASHRAE Class A3 – Includes operation up to 40ºC for up to 900 hrs. per
year
ASHRAE Class A4 – Includes operation up to 45ºC for up to 90 hrs. per
year
Shipping
-40ºC to 70ºC (-40ºF to 158ºF)
Altitude
Operating
Support operation up to 3050m with ASHRAE class deratings
Humidity
Shipping
50% to 90%, non-condensing with a maximum wet bulb of 28°C (at
temperatures from 25°C to 35°C)
Shock
Operating
, 11 mSec
Unpackaged
, velocity change is based on packaged weight
Packaged
Product Weight:
≥ 40 to < 80
Non-palletized Free Fall Height = 18 inches
Palletized (single product) Free Fall Height = NA
Vibration
Unpackaged
5 Hz to 500 Hz
2.20 g RMS random
Packaged
5 Hz to 500 Hz
1.09 g RMS random
AC-DC
Voltage
90 Hz to 132 V and 180 V to 264 V
Frequency
47 Hz to 63 Hz
Source Interrupt
No loss of data for power line drop-out of 12 mSec
Surge Non-
operating and
operating
Unidirectional
Line to earth
Only
AC Leads 2.0 kV
I/O Leads 1.0 kV
DC Leads 0.5 kV
ESD
Air Discharged
12.0 kV
Contact
Discharge
8.0 kV
Acoustics
Sound Power
Measured
Power in Watts
<300 W
≥300 W ≥600 W ≥1000 W
Servers/Rack
Mount BA
7.0 7.0 7.0 7.0
Содержание S4600LT2