Calibrating Device with Custom Calibration Sample Application
21
4
Calibrating Device with Custom
Calibration Sample Application
4.1
Process Overview
The general process to calibrate a device with the Custom Calibration Sample App
involves running the app capturing images of the target from various viewpoints, the
app optimizes the calibration parameters based on the captured images and writes the
results to a XML file. The user then run CustomRW calibration data R/W tool to read the
parameters from the XML file and write them to the device.
4.2
Connect Device to Computer
Connect the device through the USC cable to the PC where Custom Calibration Sample
App locates.
4.3
Running Custom Calibration Sample Application
4.3.1
Starting Application
Use Windows explorer to browse to CustomCalibration\bin directory and find the
CustomCalibrationTest.exe and double click it to start running.