Fan Motor Performance
The fan power requirements for proper operation are given Table 4.
Table 4. Fan Electrical Performance Requirements
Requirement Value
Maximum Average fan current draw
1.5 A
Fan start-up current draw
2.2 A
Fan start-up current draw maximum duration
1.0 second
Fan header voltage
12 V ± 5%
Tachometer output
2 pulse per revolution
Tachometer output signal
Open-collector (open-drain)
PWM signal input frequency
21 kHz to 28 kHz
PWM signal pull up in fan
3.3 V (recommended max);
5.25 V (absolute max)
PWM signal current source
Imax = 5 mA (short circuit current)
PWM signal maximum voltage for logic low
VIL = 0.8 V
PWM compliant function
RPM must be within spec for specified duty
cycle
In addition to comply with overall thermal requirements (see Section
5.1.1), and the
general environmental reliability requirements (see Section
5.2) the fan should meet
the following performance requirements:
•
Mechanical wear out represents the highest risk reliability parameter for fans. The
capability of the functional mechanical elements (ball bearing, shaft, and tower
assembly) must be demonstrated to a minimum useful lifetime of 50,000 hours.
•
In addition to passing the environmental reliability tests described in Section
5.2,
the fan must demonstrate adequate performance after 7,500 on/off cycles with
each cycle specified as 3 minutes on, 2 minutes off, at a temperature of 70 °C.
See the Fan Specification for 4-wire PWM Controlled Fans for additional details on the
fan specification.
Содержание QX68000 Core 2 Extreme
Страница 30: ...LGA775 Socket Heatsink Loading 30 Thermal and Mechanical Design Guidelines...
Страница 74: ...Heatsink Clip Load Metrology 74 Thermal and Mechanical Design Guidelines...
Страница 76: ...Thermal Interface Management 76 Thermal and Mechanical Design Guidelines...
Страница 96: ...Case Temperature Reference Metrology 96 Thermal and Mechanical Design Guidelines...
Страница 108: ...Legacy Fan Speed Control 108 Thermal and Mechanical Design Guidelines...
Страница 112: ...BTX System Thermal Considerations 112 Thermal and Mechanical Design Guidelines...