Intel N440BX Скачать руководство пользователя страница 10

10

9.

 

Select the 

DAC960 NT SCSI Driver

 in the list and press <

ENTER

>.

10.

 

Repeat Steps 6 and 7 above, if you have drivers to install for other controllers, such as an IDE/ATAPI
CD-ROM.  When prompted, insert the manufacturer’s supplied hardware.  When you have no other
drivers to install, or when you have finished press <ENTER> to continue installation.

11.

 

Insert Windows NT 4.x setup diskette #3 when prompted.

12.

 

Follow the rest of the on screen instructions to complete the NT installation.

Troubleshooting

This section is not intended to be a tutorial on repair and system troubleshooting.  It is intended to provide hints for
the technician.  If the problem system has just been assembled, a first step should be to check the system against the
assembly procedures in the printed Intel N440BX (or T440BX) Server Board Quick Start Guide’s and the electronic
Intel N440BX (or T440BX) Server Board Product guides found on their respective Resource CD in the Server Board
Kit.

Trouble Shooting Information

Problem

Possible Solution

System fails to boot

General: Check power. Check that cables, connectors and socketed
components are properly seated.  Remove all components except minimal
memory and a processor and reboot. If possible check individual
components (especially processors and memory) in a known good system.
1. 

 

Check for processor termination card in empty slot 1.

2. 

 

Check for approved memory DIMM modules.

3. 

 

Ensure that the power supply is attached to correct connectors (two
along the edge of the board for the two Intel chassis, one closer to the
center of the board for 20-pin ATX standard power supply).

4. 

 

Ensure the Power Supply is providing at least 800mA of +5V standby
current to support WOL*, if not, disable WOL via Server Board
jumper.

5. 

 

Ensure correct (EDO) cache memory installed in the Mylex
AcceleRAID 200.

System will not boot from the N440BX
Server Board Resource CDROM

1.

 

Incorrect BIOS Boot priority order. Press <F2> during the server’s
POST and configure in BIOS set-up.

2.

 

In the AcceleRAID BIOS settings (accessed by “Alt-M” during boot),
“BIOS” must be enabled and “CD-ROM boot” enabled.

AcceleRAID 200 not properly
recognized during POST

1.

 

Ensure AcceleRAID 200 Card is inserted into PCI Slot 3

2.

 

Ensure <SCSI Option ROM> disabled in server BIOS setup

OS “hangs” during install

1.

 

Ensure Symbios drivers are not installed, use Mylex AcceleRAID 200
drivers.  If not, both devices will attempt to take control of the SCSI
channels on the Server Board

2.

 

Cannot install Microsoft NT by booting off the CDROM.  Must use
floppies.

“System Drives Dead” after NT install
attempt

You have attempted to install NT 4.0 by booting off the CDROM.  This
does not work.  The Mylex controller thinks that the drives are dead.  To fix
you must run DACCF again and “restore” your configuration from floppy
or re-enter the configuration exactly as entered when the drives were
created.

Other

For further support information, check

http://support.intel.com/support/motherboards/server/n440bx
http://support.intel.com/support/motherboards/server/t440bx

Содержание N440BX

Страница 1: ...N440BX T440BX Server Boards Installation and Operating Summary of the Mylex AcceleRAID 200 RAID Controller Revision 1 0 September 2 1998 ...

Страница 2: ...s including liability or warranties relating to fitness for a particular purpose merchantability or infringement of any patent copyright or other intellectual property right Intel products are not intended for use in medical life saving or life sustaining applications Intel may make changes to specifications and product descriptions at any time without notice The N440BX may contain design defects ...

Страница 3: ...RAID 200 HARDWARE STARTING THE DACCF UTILITY 5 USING AUTOMATIC CONFIGURATION TO CREATE A RAID5 ARRAY WITH 3 OR MORE DRIVES 7 USING NEW CONFIGURATION TO CREATE A CUSTOM RAID ARRAY 7 BACKING UP THE CONFIGURATION INFORMATION TO A FLOPPY 8 INITIALIZING THE RAID ARRAY 8 EXITING THE DACCF UTILITY SOFTWARE 8 INSTALLING AN OPERATING SYSTEM 9 TROUBLESHOOTING 10 APPENDIX A MYLEX ACCELERAID 200 DRIVER SUPPOR...

Страница 4: ...ot Intel s N440BX T440BX NA440BX NC440BX are examples of such Server boards and systems AcceleRAID adapters bring the performance and fault tolerance of RAID to entry level and mid range server applications at the lowest overall price On Intel N440BX and T440BX Server Boards control of the on board SCSI channels is given to the zero channel RAID controller by routing the interrupts from the on boa...

Страница 5: ...l drives or New Configuration to create a custom RAID array 4 Save Backup the configuration to a floppy 5 Initialize the system drives 6 Install the Network Operating system Installing the Mylex AcceleRAID 200 hardware starting the DACCF utility Hardware configuration used for this example Intel N440BX Server Board Intel Astor chassis two Intel Pentium II Processors with 100MHz System Bus operatin...

Страница 6: ...e connected to the RAID Controller In the Astor chassis the managed SCSI Hot Swap Back Plane HSBP assigns SCSI device IDs and ensures proper termination Jumpers on the HSBP control configuration of SCSI ID s for the Hot Swap drives Consult the Astor Chassis Subassembly Product Guide for further information on jumper settings and their definitions 5 Power on the system and enter the BIOS Setup by p...

Страница 7: ...he Main Menu of the DACCF utility choose New Configuration 2 Under the New Configuration menu choose 1 Define Pack 3 The table on the left shows boxes for each possible drive location A status will appear in each box for which a drive is installed under the appropriate channel and drive ID Drives that are installed and ready will have RDY displayed ONL represents drives that are currently online A...

Страница 8: ...second copy of the configuration information also One copy can be taken off site and the other taped into the server chassis to ensure it will be available if needed 9 Proceed to the next section Initializing the RAID array to prepare the drives for use Initializing the RAID array 1 From the main menu choose 05 Initialize System Drive 2 From the Initialize System Drive menu choose 1 Select System ...

Страница 9: ...dapter will be reported as having failed If this is done the configuration will have to be re entered or restored from backup floppy The installation requires using the three install floppy diskettes in addition to the CD this allows the user to perform a Custom installation which allows skipping detection of the Symbios Logic SCSI controller and separate installation the Mylex drivers Below is a ...

Страница 10: ...ure that the power supply is attached to correct connectors two along the edge of the board for the two Intel chassis one closer to the center of the board for 20 pin ATX standard power supply 4 Ensure the Power Supply is providing at least 800mA of 5V standby current to support WOL if not disable WOL via Server Board jumper 5 Ensure correct EDO cache memory installed in the Mylex AcceleRAID 200 S...

Страница 11: ...celeRAID 200 Driver Support Operating System Driver Support Windows NT 3 51 4 0 Advanced Server NetWare 3 x 4 x non NWPA SMP SCO UnixWare 2 1 7 0 UNIX OSR 5 x OS 2 x 3 x SMP DOS 5 x 6 x and above Mylex web site www mylex com ...

Отзывы: