MP Configuration Table
Version 1.4
4-7
Table 4-3.
Base
MP Configuration
Table
Entry Types
Entry Description
Entry Type Code*
Length
(in bytes)
Comments
Processor
0
20
One entry per processor.
Bus
1
8
One entry per bus.
I/O APIC
2
8
One entry per I/O APIC.
I/O Interrupt Assignment
3
8
One entry per bus interrupt source.
Local Interrupt Assignment
4
8
One entry per system interrupt
source.
* All other type codes are reserved.
4.3.1 Processor Entries
Figure 4-4 shows the format of each processor entry, and Table 4-4 defines the fields.
RESERVED
RESERVED
31
0
3
7
4
8
11
12
15
16
19
20
23
24
27
28
CPU SIGNATURE
LOCAL APIC ID
CPU FLAGS
FEATURE FLAGS
31
0
3
7
4
8
11
12
15
16
19
20
23
24
27
28
00H
04H
08H
0CH
10H
LOCAL APIC
VERSION #
ENTRY TYPE
0
E
N
RESERVED
B
P
Figure 4-4. Processor Entry
In systems that use the MP configuration table, the only restriction placed on the assignment of
APIC IDs is that they
be unique
. They do not need to be consecutive. For example, it is possible
for only APIC IDs 0, 2, and 4 to be present.