164
Chapter 7 Power System
A redundant power system uses a power share backplane to distribute
power to the server. The backplane implements these server management
features:
•
I
2
C bus
•
Power supply failure
•
Maximum current
•
Current usage
•
Number of power supplies installed in the server’s power system
•
Redundant mode
•
240 VA limit
The current sensing feature of the power share backplane shuts down the
entire power system if any single output from the backplane to the system
board or peripherals exceeds 240 VA. Current sensing limits the energy
supplied by the power share backplane to levels generally accepted as
operator accessible areas—less than 240 VA for the CSA Level 3 category—
without the use of interlocks.
If a power supply fails in a redundant power system, the yellow power
supply failure LED on the front panel starts flashing. The power supply can
be easily replaced without shutting down the system. The power supply is
inserted through the back of the chassis and held in place with four screws.
Power System Voltages
+3.3V
+5V
+12V
-5V
-12V
One power supply, entry level nonredundant
(Total combined output power of +3.3 V and +5 V
should not exceed 178W)
13 A
32 A
15.5
A
0.25 A
0.5 A
Two power supplies, entry level redundant
13 A*
30 A
13.5
A
0.25 A
0.5 A
Two power supplies, maximum level
nonredundant
18 A
**
46 A
29 A
0.5 A
1.0 A
Three power supplies, maximum level redundant
18 A
**
46 A
29 A
0.5 A
1.0 A
*
No more than 5A to be used by PCI slots.
**
No more than 10A to be used by PCI slots.
Содержание MB440LX
Страница 1: ...Intel MB440LX System Installation Guide...
Страница 6: ...1 6 Your Chapter Title Goes Here...
Страница 16: ...16 Contents...
Страница 26: ...26 Chapter 1 Server Description OM05793 Figure 1 4 Security Padlocks...
Страница 48: ...48 Chapter 2 Installing The System...
Страница 78: ...78 Chapter 3 Configuring The System...
Страница 100: ...100 Chapter 4 Working Inside Your System OM04639 Figure 4 11 Installing an ISA Add in Board Component side Up...
Страница 101: ...M440LX Server System Product Guide 101 OM04640 Figure 4 12 Installing a PCI Add in Board Component side Down...
Страница 114: ...114 Chapter 4 Working Inside Your System OM05791A 1 2 3 Figure 4 19 Lithium Back up Battery...
Страница 116: ...116 Chapter 4 Working Inside Your System OM05268 Figure 4 20 Removing the Front Panel Board...
Страница 118: ...118 Chapter 4 Working Inside Your System OM05278 Figure 4 21 Front Panel Fans...
Страница 127: ...M440LX Server System Product Guide 127 OM05771 Figure 4 26 Removing the Power Share Backplane...
Страница 132: ...132 Chapter 4 Working Inside Your System...
Страница 137: ...M440FX Server System Product Guide 137 OM06470 1 2 Figure 5 2 Installing a Hard Disk Drive...
Страница 200: ...200 Chapter 9 I O Ports and Connectors...
Страница 224: ...224 Chapter 10 Solving Problems...