Intel® Server System M50CYP1UR Family System Integration and Service Guide
25
Figure 10. Setting the Processor Heat Sink Anti-tilt Wires to the Outward Position
5.
Set the anti-tilt wires to the outward position.
6.
Turn the heat sink over and place it bottom side up on a flat surface.
7.
Remove the plastic protective film from the Thermal Interface Material (TIM).
•
Figure 11. Pin 1 Indicator of Processor Carrier Clip
8.
Align pin 1 indicator of processor carrier clip with the corner cut-out on the heat sink. For the EVAC heat
sink, align the processor carrier clip and the heat sink as shown in the above figure.
Note:
In a standard heat sink there are two cut-out corners, either can be used to align pin 1 indicators.
9.
Gently press down the heat sink onto the processor carrier clip until it clicks into place.
10.
Ensure all four heat sink corners are securely latched to the processor carrier clip tabs.