background image

Intel® Integrated RAID Module SROMBSASMR Hardware User’s Guide

21

English

Read all caution and safety statements in this document before performing any of the 

instructions. See also 

Intel

®

 Server Boards and Server Chassis Safety Information

 on the 

Resource CD and/or at 

 

http://support.intel.com/support/motherboards/server/sb/cs-010770.htm

.

The power button on the system does not turn off system AC power. 

To remove AC power from the system, you must unplug each AC 

power cord from the wall outlet or power supply.

The power cord(s) is considered the disconnect device to the main 

(AC) power. The socket outlet that the system plugs into shall be 

installed near the equipment and shall be easily accessible.

SAFETY STEPS:

 Whenever you remove the chassis covers to 

access the inside of the system, follow these steps:

1. Turn off all peripheral devices connected to the system.
2. Turn off the system by pressing the power button.
3. Unplug all AC power cords from the system or from wall 

outlets.

4. Label and disconnect all cables connected to I/O connectors 

or ports on the back of the system.

5. Provide some electrostatic discharge (ESD) protection by 

wearing an antistatic wrist strap attached to chassis ground of 

the system-any unpainted metal surface-when handling 

components.

6. Do not operate the system with the chassis covers removed.

After you have completed the six SAFETY steps above, you can 

remove the system covers. To do this:

1. Unlock and remove the padlock from the back of the system if 

a padlock has been installed.

2. Remove and save all screws from the covers.
3. Remove the cover(s).

For proper cooling and airflow, always reinstall the chassis covers 

before turning on the system. Operating the system without the 

covers in place can damage system parts. To install the covers:

1. Check first to make sure you have not left loose tools or parts 

inside the system.

2. Check that cables, add-in cards, and other components are 

properly installed.

3. Attach the covers to the chassis with the screws removed 

earlier, and tighten them firmly.

4. Insert and lock the padlock to the system to prevent 

unauthorized access inside the system.

5. Connect all external cables and the AC power cord(s) to the 

system.

 

 

 

Содержание AXXROMBSASMR

Страница 1: ...Intel Integrated RAID Module SROMBSASMR AXXROMBSASMR Hardware User s Guide Intel Order Number E58607 003...

Страница 2: ...NTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE MERCHANTABILITY OR INFRINGEMENT OF ANY PATENT COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT Intel products...

Страница 3: ...who are designing an Intel Integrated RAID Module SROMBSASMR for their RAID system Anyone installing an Intel Integrated RAID Module SROMBSASMR in their RAID system Organization This document include...

Страница 4: ...iv Intel Integrated RAID Module SROMBSASMR Hardware User s Guide...

Страница 5: ...on 7 Requirements 7 Installing the RAID Module 7 Configuring the RAID Module 11 Replacing a Controller Resolving a Config Mismatch 11 Chapter 3 Intel Integrated RAID Module SROMBSASMR Characteristics...

Страница 6: ...vi Intel Integrated RAID Module SROMBSASMR Hardware User s Guide...

Страница 7: ...dware User s Guide vii List of Figures Figure 1 Installing the Snap Standoff 8 Figure 2 Installing the Intel Integrated RAID Module SROMBSASMR 9 Figure 3 Connecting Cable between the RAID Module and D...

Страница 8: ...viii Intel Integrated RAID Module SROMBSASMR Hardware User s Guide...

Страница 9: ...grated RAID Module SROMBSASMR Hardware User s Guide ix List of Tables Table 1 Jumper Description 13 Table 2 Technical Specifications 14 Table 3 Array Performance Features 14 Table 4 Fault Tolerance Fe...

Страница 10: ...x Intel Integrated RAID Module SROMBSASMR Hardware User s Guide...

Страница 11: ...ry AXXRSBBU3 provides cached data protection for the RAID module even during system failures Benefits of SAS and SATA SAS is a serial point to point enterprise level device interface that leverages th...

Страница 12: ...System SR1625UR Intel Server System SR2600UR Intel Server System SR2625UR Intel Server Board S5520HC S5500HCV Intel Workstation Board S5520SC Intel Server Board S5500WB Note Additional Intel Server B...

Страница 13: ...d array configuration and management utilities provide Online Capacity Expansion OCE adds space to existing drive or new drive See Appendix A Drive Roaming and Drive Migration Install for limitations...

Страница 14: ...VRAM viewable from OS Event Log Intel RAID Web Console 2 CIM and LEDs Multiple cache options allow configuration specific performance optimization Write back Faster because it does not wait for the di...

Страница 15: ...ves Allows multiple initiators to address a single target in a fail over configuration through an expander Online Capacity Expansion and RAID Level Migration Rules Migration must occur to the same or...

Страница 16: ...6 Intel Integrated RAID Module SROMBSASMR Hardware User s Guide...

Страница 17: ...ments see step 6 in Installing the RAID Module Note Intel Corporation strongly recommends using an uninterruptible power supply UPS Installing the RAID Module To install the RAID Module follow these s...

Страница 18: ...Board AF003047 A Figure 1 Installing the Snap Standoff 4 Attach the Intel Integrated RAID Module SROMBSASMR module card to the matching server workstation board connector and press the module card fi...

Страница 19: ...your server workstation board or chassis documentation Make sure the cables are properly connected to the controller Note System throughput problems can occur if non standard SAS cables are used To mi...

Страница 20: ...AID Module SROMBSASMR Hardware User s Guide Figure 3 Connecting Cable between the RAID Module and Drives Backplane 7 Install the server system cover and connect the power cords See your server system...

Страница 21: ...s the PCI slot scanning order used by the server board 3 Follow the instructions in the Intel RAID Software User s Guide Document Number D29305 00x to configure the RAID module and to install the oper...

Страница 22: ...12 Intel Integrated RAID Module SROMBSASMR Hardware User s Guide...

Страница 23: ...Connection to SAS SATA devices J1 SAS SATA Port 0 J2 SAS SATA Port 1 J3 SAS SATA Port 2 J4 SAS SATA Port 3 J5 Board to board connector for Battery Backup Unit 20 pin connector Provides an interface to...

Страница 24: ...667 MHz SDRAM optional battery backup Firmware 4 MB in reflashable flash ROM Compatible devices 2 5 inch and 3 5 inch SAS or SATA 3 0 drives Non disk devices including expanders Can support drives of...

Страница 25: ...ecking and Indication Parity generation and checking automatic consistency checking Patrol reads Activity and fault LEDs Multiple retries Logs in NVRAM event log CIM Smart Intel RAID Web Console 2 Fau...

Страница 26: ...he charging circuitry for the battery pack on the optional Intel RAID Smart Battery AXXRSBBU3 is 12 V During fast charging of the battery pack expected power consumption is 230 mA rise in 12V current...

Страница 27: ...o use drive roaming follow these steps 1 Turn off the power to the system all drives enclosures and system components Remove the power cord s 2 Remove the server cover For instructions see your server...

Страница 28: ...off the power to the system all drives enclosures and system components Remove the power cord s 3 Remove the server cover For instructions see your server system documentation 4 Disconnect the cables...

Страница 29: ...elp protect your computer system from sudden transient increases and decreases in electrical power use a surge suppressor line conditioner or uninterruptible power supply Be sure nothing rests on your...

Страница 30: ...revent static damage discharge static electricity from your body before you touch any of your computer s electronic components such as the microprocessor You can do so by touching an unpainted metal s...

Страница 31: ...disconnect all cables connected to I O connectors or ports on the back of the system 5 Provide some electrostatic discharge ESD protection by wearing an antistatic wrist strap attached to chassis grou...

Страница 32: ...r Steckdose bzw dem Netzger t um den Stromanschlu des Systems zu unterbrechen Die Stromkabel sind das Unterbrechungsger t zur Hauptstromquelle Die Steckdose in die das System gesteckt wird sollte sich...

Страница 33: ...en zu vermeiden 6 Schalten Sie das System niemals ohne ordnungsgem montiertes Geh use ein Zur ordnungsgem en K hlung und L ftung mu die Geh useabdeckung immer wieder vor dem Einschalten installiert we...

Страница 34: ...sants portez une bande antistatique pour poignet et reliez la la masse du syst me toute surface m tallique non peinte du bo tier 6 Ne faites pas fonctionner le syst me tandis que le bo tier est ouvert...

Страница 35: ...equipo y ser de f cil acceso INSTRUCCIONES DE SEGURIDAD Cuando extraiga la tapa del chasis para acceder al interior del sistema siga las siguientes instrucciones 1 Apague todos los dispositivos perif...

Страница 36: ...ma y bloqu elo para impedir que pueda accederse al mismo sin autorizaci n 5 Conecte todos los cables externos y los cables de alimentaci n CA al sistema Si el sistema ha estado en funcionamiento el mi...

Страница 37: ...ro del sistema qualora ve ne fosse uno installato 2 Togliere e mettere in un posto sicuro tutte le viti delle coperture 3 Togliere le coperture Per il giusto flusso dell aria e raffreddamento del sist...

Страница 38: ...28 Intel Integrated RAID Module SROMBSASMR Hardware User s Guide...

Страница 39: ...mation Product Safety and EMC Compliance This Intel RAID Module has been evaluated for regulatory compliance as an Intel end system and is included as part of the end system certification For informat...

Страница 40: ...30 Intel Integrated RAID Module SROMBSASMR Hardware User s Guide...

Отзывы: