background image

Intel® Integrated RAID Module SROMBSASMR Hardware User’s Guide

7

2

Intel

®

 Integrated RAID Module 

SROMBSASMR Hardware Installation

Requirements

Intel

®

 Integrated RAID Module SROMBSASMR, with the provided standoffs

A host system with an available 50-pin PCI Express* connector

Resource CD, which contains drivers and documentation

SAS or SATA 3.0 hard drives

Four provided SAS/SATA cables (for cable requirements, see step 6 in 

“Installing 

the RAID Module”

)

Note:

Intel Corporation strongly recommends using an uninterruptible power supply (UPS). 

Installing the RAID Module

To install the RAID Module, follow these steps:

1. Turn off the power to the system, all drives, enclosures, and system components. 

Remove the power cord(s).

2. Remove the server cover. For instructions, see your server system documentation.
3. Insert the three snap standoffs into the matching holes in the server/workstation 

board. To locate the matching module card slot on your server/workstation board, 

see your server/workstation board documentation. 

Содержание AXXROMBSASMR

Страница 1: ...Intel Integrated RAID Module SROMBSASMR AXXROMBSASMR Hardware User s Guide Intel Order Number E58607 003...

Страница 2: ...NTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE MERCHANTABILITY OR INFRINGEMENT OF ANY PATENT COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT Intel products...

Страница 3: ...who are designing an Intel Integrated RAID Module SROMBSASMR for their RAID system Anyone installing an Intel Integrated RAID Module SROMBSASMR in their RAID system Organization This document include...

Страница 4: ...iv Intel Integrated RAID Module SROMBSASMR Hardware User s Guide...

Страница 5: ...on 7 Requirements 7 Installing the RAID Module 7 Configuring the RAID Module 11 Replacing a Controller Resolving a Config Mismatch 11 Chapter 3 Intel Integrated RAID Module SROMBSASMR Characteristics...

Страница 6: ...vi Intel Integrated RAID Module SROMBSASMR Hardware User s Guide...

Страница 7: ...dware User s Guide vii List of Figures Figure 1 Installing the Snap Standoff 8 Figure 2 Installing the Intel Integrated RAID Module SROMBSASMR 9 Figure 3 Connecting Cable between the RAID Module and D...

Страница 8: ...viii Intel Integrated RAID Module SROMBSASMR Hardware User s Guide...

Страница 9: ...grated RAID Module SROMBSASMR Hardware User s Guide ix List of Tables Table 1 Jumper Description 13 Table 2 Technical Specifications 14 Table 3 Array Performance Features 14 Table 4 Fault Tolerance Fe...

Страница 10: ...x Intel Integrated RAID Module SROMBSASMR Hardware User s Guide...

Страница 11: ...ry AXXRSBBU3 provides cached data protection for the RAID module even during system failures Benefits of SAS and SATA SAS is a serial point to point enterprise level device interface that leverages th...

Страница 12: ...System SR1625UR Intel Server System SR2600UR Intel Server System SR2625UR Intel Server Board S5520HC S5500HCV Intel Workstation Board S5520SC Intel Server Board S5500WB Note Additional Intel Server B...

Страница 13: ...d array configuration and management utilities provide Online Capacity Expansion OCE adds space to existing drive or new drive See Appendix A Drive Roaming and Drive Migration Install for limitations...

Страница 14: ...VRAM viewable from OS Event Log Intel RAID Web Console 2 CIM and LEDs Multiple cache options allow configuration specific performance optimization Write back Faster because it does not wait for the di...

Страница 15: ...ves Allows multiple initiators to address a single target in a fail over configuration through an expander Online Capacity Expansion and RAID Level Migration Rules Migration must occur to the same or...

Страница 16: ...6 Intel Integrated RAID Module SROMBSASMR Hardware User s Guide...

Страница 17: ...ments see step 6 in Installing the RAID Module Note Intel Corporation strongly recommends using an uninterruptible power supply UPS Installing the RAID Module To install the RAID Module follow these s...

Страница 18: ...Board AF003047 A Figure 1 Installing the Snap Standoff 4 Attach the Intel Integrated RAID Module SROMBSASMR module card to the matching server workstation board connector and press the module card fi...

Страница 19: ...your server workstation board or chassis documentation Make sure the cables are properly connected to the controller Note System throughput problems can occur if non standard SAS cables are used To mi...

Страница 20: ...AID Module SROMBSASMR Hardware User s Guide Figure 3 Connecting Cable between the RAID Module and Drives Backplane 7 Install the server system cover and connect the power cords See your server system...

Страница 21: ...s the PCI slot scanning order used by the server board 3 Follow the instructions in the Intel RAID Software User s Guide Document Number D29305 00x to configure the RAID module and to install the oper...

Страница 22: ...12 Intel Integrated RAID Module SROMBSASMR Hardware User s Guide...

Страница 23: ...Connection to SAS SATA devices J1 SAS SATA Port 0 J2 SAS SATA Port 1 J3 SAS SATA Port 2 J4 SAS SATA Port 3 J5 Board to board connector for Battery Backup Unit 20 pin connector Provides an interface to...

Страница 24: ...667 MHz SDRAM optional battery backup Firmware 4 MB in reflashable flash ROM Compatible devices 2 5 inch and 3 5 inch SAS or SATA 3 0 drives Non disk devices including expanders Can support drives of...

Страница 25: ...ecking and Indication Parity generation and checking automatic consistency checking Patrol reads Activity and fault LEDs Multiple retries Logs in NVRAM event log CIM Smart Intel RAID Web Console 2 Fau...

Страница 26: ...he charging circuitry for the battery pack on the optional Intel RAID Smart Battery AXXRSBBU3 is 12 V During fast charging of the battery pack expected power consumption is 230 mA rise in 12V current...

Страница 27: ...o use drive roaming follow these steps 1 Turn off the power to the system all drives enclosures and system components Remove the power cord s 2 Remove the server cover For instructions see your server...

Страница 28: ...off the power to the system all drives enclosures and system components Remove the power cord s 3 Remove the server cover For instructions see your server system documentation 4 Disconnect the cables...

Страница 29: ...elp protect your computer system from sudden transient increases and decreases in electrical power use a surge suppressor line conditioner or uninterruptible power supply Be sure nothing rests on your...

Страница 30: ...revent static damage discharge static electricity from your body before you touch any of your computer s electronic components such as the microprocessor You can do so by touching an unpainted metal s...

Страница 31: ...disconnect all cables connected to I O connectors or ports on the back of the system 5 Provide some electrostatic discharge ESD protection by wearing an antistatic wrist strap attached to chassis grou...

Страница 32: ...r Steckdose bzw dem Netzger t um den Stromanschlu des Systems zu unterbrechen Die Stromkabel sind das Unterbrechungsger t zur Hauptstromquelle Die Steckdose in die das System gesteckt wird sollte sich...

Страница 33: ...en zu vermeiden 6 Schalten Sie das System niemals ohne ordnungsgem montiertes Geh use ein Zur ordnungsgem en K hlung und L ftung mu die Geh useabdeckung immer wieder vor dem Einschalten installiert we...

Страница 34: ...sants portez une bande antistatique pour poignet et reliez la la masse du syst me toute surface m tallique non peinte du bo tier 6 Ne faites pas fonctionner le syst me tandis que le bo tier est ouvert...

Страница 35: ...equipo y ser de f cil acceso INSTRUCCIONES DE SEGURIDAD Cuando extraiga la tapa del chasis para acceder al interior del sistema siga las siguientes instrucciones 1 Apague todos los dispositivos perif...

Страница 36: ...ma y bloqu elo para impedir que pueda accederse al mismo sin autorizaci n 5 Conecte todos los cables externos y los cables de alimentaci n CA al sistema Si el sistema ha estado en funcionamiento el mi...

Страница 37: ...ro del sistema qualora ve ne fosse uno installato 2 Togliere e mettere in un posto sicuro tutte le viti delle coperture 3 Togliere le coperture Per il giusto flusso dell aria e raffreddamento del sist...

Страница 38: ...28 Intel Integrated RAID Module SROMBSASMR Hardware User s Guide...

Страница 39: ...mation Product Safety and EMC Compliance This Intel RAID Module has been evaluated for regulatory compliance as an Intel end system and is included as part of the end system certification For informat...

Страница 40: ...30 Intel Integrated RAID Module SROMBSASMR Hardware User s Guide...

Отзывы: